-
Randomized Controlled Trial
Correlation of measured and calculated serum osmolality during mannitol or hypertonic saline infusion in patients after craniotomy: a study protocol and statistical analysis plan for a randomised controlled trial.
- Qian Li, Ming Xu, and Jian-Xin Zhou.
- Department of Critical Care Medicine, Beijing Tiantan Hospital, Capital Medical University, Beijing, China.
- BMJ Open. 2014 Jan 1;4(4):e004921.
IntroductionBrain oedema is a major complication after craniotomy. Hyperosmolar agents have been used as the medical treatment for this condition. Measurement and estimation of serum osmolality during hyperosmolar agent infusion is of clinical importance to evaluate clinical efficacy, adjust dosage and avoid side effects. However, several studies have shown that calculated serum osmolality may lead to a systematic bias compared with direct measurement. In the present study, mannitol or hypertonic saline (HS) will be used in patients after elective craniotomy. We aim to determine the accuracy of serum osmolality estimation during the application of hyperosmolar agent.Methods And AnalysisThe study is a prospective, randomised, double-blinded, controlled, parallel-group design. Adult patients requiring the use of hyperosmolar agents for the prevention or treatment of postoperative brain oedema are enrolled and assigned randomly to one of the two treatment study groups, labelled as 'M group' and 'HS group'. Patients in the M and HS groups receive intravenous infusion of 125 mL of either 20% mannitol or 3.1% sodium chloride solution, respectively. Data will be collected immediately before the infusion of study agents, 15, 30, 60, 120, 240 and 360 min after the start of infusion of experimental agents, which includes serum osmolality, concentration of serum sodium, potassium, urea and glucose. Serum osmolality will be measured by means of freezing point depression. Estimated serum osmolality will also be calculated by using four formulas published previously. Osmole gap is calculated as the difference between the measured and the estimated values. The primary endpoint is the correlation of measured and estimated serum osmolality during hyperosmolar agent infusion.Ethics And DisseminationThe study was approved by the International Review Board (IRB) of Beijing Tiantan Hospital, Capital Medical University. Study findings will be disseminated through peer-reviewed publications and conference presentations.Trial Registration NumberClinicalTrials.gov identifier: NCT02037815.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.