Randomized Controlled Trial Clinical Trial
Use of the rapid/shallow breathing index as an indicator of patient work of breathing during pressure support ventilation.
- J A Johannigman, K Davis, R S Campbell, R D Branson, F A Luchette, and J M Hurst.
- Department of Surgery, University of Cincinnati College of Medicine, Ohio 45267-0558, USA.
- Surgery. 1997 Oct 1;122(4):737-40; discussion 740-1.
BackgroundMeasuring patient work of breathing (WOBpt) has been suggested to provide safe, aggressive weaning from mechanical ventilation. We compared WOBpt and pressure-time-product (PTP) to routine weaning parameters [breath rate (f), tidal volume (VT), frequency/tidal volume ratio (f/VT)] at different levels of pressure support ventilation (PSV).MethodsFifteen patients in the surgical intensive care unit requiring prolonged weaning (more than 3 days) were entered in the study. A balloon-tipped esophageal catheter was placed and position confirmed by inspection of pressure and flow waveforms. Each patient was randomly assigned to breathe with 5, 10, 15, and 20 cm H2O of PSV. After 30 minutes, 40 breaths were recorded and analyzed. Measurement of WOBpt PTP, f, VT, and f/VT were made using the Bicore CP-100 monitor. Mean values for each parameter were calculated. PTP and WOBpt were plotted against f/VT to determine correlation coefficient.ResultsPTP, WOBpt and f/VT decreased in a stepwise fashion as PSV was increased. The f/VT correlated most closely with WOBpt (r = 0.983) and PTP (r = 0.972). Monitoring f alone also correlated with WOBpt (r = 0.894) and PTP (r = 0.881). All patients were weaned from the ventilator (mean duration, 22 +/- 5.9 days). Nine patients required tracheostomy before final liberation from the ventilator (mean duration, 22 +/- 5.9 days). Nine patients required tracheostomy before final liberation from the ventilator.ConclusionsDirect measurement of WOBpt is invasive, expensive, and' may be confusing to clinicians. Monitoring f/VT may be useful when changing PSV during weaning.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.