• Journal of critical care · Jun 2014

    Randomized Controlled Trial

    Cycling-off modes during pressure support ventilation: Effects on breathing pattern, patient effort, and comfort.

    • Fabrícia C Hoff, Mauro R Tucci, Marcelo B P Amato, Laura J Santos, and Josué A Victorino.
    • Intensive Care Unit, Hospital Mãe de Deus, Porto Alegre, Brazil; Graduate Program in Medical Sciences, Universidade Federal do Rio Grande do Sul, Porto Alegre, Brazil.
    • J Crit Care. 2014 Jun 1; 29 (3): 380-5.

    PurposeExpiratory asynchrony during pressure support ventilation (PSV) has been recognized as a cause of patient discomfort, increased workload, and impaired weaning process. We evaluated breathing pattern, patient comfort, and patient effort during PSV comparing 2 flow termination criteria: fixed at 5% of peak inspiratory flow vs automatic, real-time, breath-by-breath adjustment within the range of 5% to 55%.Materials And MethodsRandomized crossover clinical trial. Sixteen awake patients, in the process of weaning, under PSV for more than 24 hours were subjected to 3 phases of PSV, each lasting 1 hour and using 1 of the 2 aforementioned termination criteria.ResultsEffective pressure support during automatic adjustment (AA) was 12.5±3.2 cm H2O vs 12.5±3.9 cm H2O (P=.9) with the fixed termination criterion, and external positive end-expiratory pressure was 6.2±1.8 vs 6.8±2 (P<.05). The effective termination criterion was higher during AA (31% [23-39] vs 12% [6-23]; P<.01), but without producing premature breath terminations. Pressure overshoots and alternative cycling-off were also decreased. Throughout the AA period, we observed a higher respiratory rate (24±8 breaths/min vs 19±6 breaths/min; P<.001), lower tidal volume (484 ± 88 mL vs 518±102 mL; P<.001), and shorter inspiratory times (1.0±0.3 seconds vs 1.3±0.3 seconds; P<.001). Automatic adjustment was associated with lower airway occlusion pressure after 0.1 second (P0.1) (1.8±0.9 cm H2O vs 2.4±1 cm H2O; P<.01), lower pressure-time product to trigger the ventilator, and lower subjective discomfort (visual analog scale, 3.7±1.3 vs 4.5±1.2; P<.001).ConclusionsWhen compared with a fixed termination criterion, the use of a variable, real-time-adjusted termination criterion improved some indices of patient-ventilator synchrony, producing better breathing pattern, less discomfort, and slightly lower patient effort during PSV.Copyright © 2014 Elsevier Inc. All rights reserved.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…