Comparative Study
Quadriphasic waveforms are superior to triphasic waveforms for transthoracic defibrillation in a cardiac arrest swine model with high impedance.
- Yi Zhang, Benjamin Rhee, Loyd R Davies, M Bridget Zimmerman, David Snyder, Janice L Jones, and Richard E Kerber.
- The Cardiovascular Center, College of Medicine, University of Iowa Hospital, Department of Internal Medicine, 200 Hawkins Drive, Iowa City, IA 52242, USA.
- Resuscitation. 2006 Feb 1;68(2):251-8.
BackgroundWe have demonstrated previously that triphasic waveform shocks were superior to biphasic waveform shocks for transthoracic defibrillation. Our purpose was to compare the efficacy and safety of quadriphasic versus triphasic shocks for transthoracic defibrillation in a porcine model.MethodsSixteen adult swine (19-25 kg, mean: 21.5 kg) were deeply anesthetized and intubated. To simulate impedance of the human chest, fixed electrical resistors (25 or 50 ohms) was placed in series with the defibrillator and the chest of each pig. After 30 s of electrically induced VF, each pig received transthoracic shocks, using either a truncated exponential triphasic waveform (5 ms positive pulse duration, 5 ms negative pulse duration and 5 ms positive pulse duration, total waveform duration 15 ms) or a quadriphasic waveform (5/5/5/5 ms, total waveform duration 20 ms). Each pig received transthoracic triphasic and quadriphasic shocks at three selected energy levels (50, 100 and 150 J) in random sequence. Four shocks were delivered at each energy level to construct an energy versus % success curve. Success was defined as VF termination at 5 s after shock. The total shocks were divided into three groups based on the delivered energy actually delivered to the animal: <40, 40-65 and >65 J. Delivered energy = (animal impedance/total impedance) times selected energy of the shock.ResultsFor high-impedance animals (86-102 ohms), quadriphasic waveform shocks achieved significantly higher percent shock success than triphasic shocks for the termination of VF at the energy levels of >65 J actually delivered (quadriphasic 72.7+/-12.2%, triphasic 38.9+/-7.7%, p<0.02). No differences in the shock success between quadriphasic and triphasic waveforms were found for other two energy levels. There were no differences in ventricular tachycardia or asystole after shocks between quadriphasic and triphasic waveforms.ConclusionIn this porcine model, 20 ms (5/5/5/5) quadriphasic shocks were superior to 15 ms (5/5/5) triphasic shocks for transthoracic defibrillation in animals with impedances that simulated high impedance in humans.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.