Comparative Study
Transgastric continuous-wave Doppler to determine cardiac output.
- W E Katz, T A Gasior, J J Quinlan, and J Gorcsan.
- Department of Medicine, University of Pittsburgh Medical Center, Pennsylvania 15213.
- Am. J. Cardiol. 1993 Apr 1;71(10):853-7.
AbstractA new method to measure cardiac output using transgastric continuous-wave Doppler was evaluated in 31 consecutive patients undergoing cardiac surgery with simultaneous measurement of cardiac output by the thermodilution technique. A 5 MHz single-plane imaging/5 MHz continuous-wave Doppler transesophageal transducer was used to image the left ventricular outflow tract, aortic valve and ascending aorta from a modified transgastric short-axis plane. The continuous-wave Doppler cursor was aligned parallel with blood flow across the aortic valve to obtain the maximal Doppler velocity spectra. Stroke volume was obtained by multiplying the mean Doppler flow velocity integral by the aortic annulus area, which was calculated from its diameter measured from the esophageal 5-chamber view. The stroke volume was multiplied by heart rate to yield cardiac output. A total of 57 simultaneous thermodilution and Doppler studies were attempted. Doppler data were technically limited for 2 patients both before and after cardiopulmonary bypass and for 3 patients before cardiopulmonary bypass with a result of 50 adequate studies of 57 (88%) attempted. The Doppler-derived cardiac outputs were correlated with the simultaneous measurements of cardiac output by the thermodilution technique. Linear regression analysis revealed a close correlation with R = 0.91, SEE = 0.8 liter/min, and y = 1.01x + 0.2 (p < 0.001). In conclusion, transgastric continuous-wave Doppler across the aortic valve is a promising new technique that may be used in selected patients for accurate measurement of cardiac output.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.