• Spine · Aug 2006

    Does computer-assisted spine surgery reduce intraoperative radiation doses?

    • Florian T Gebhard, Michael D Kraus, Eugen Schneider, Ulrich C Liener, Lothar Kinzl, and Markus Arand.
    • Department of Orthopaedic Trauma, Hand- and Reconstructive Surgery, University of Ulm Hospital, Ulm, Germany. florian.gebhard@uniklinik-ulm.de
    • Spine. 2006 Aug 1;31(17):2024-7; discussion 2028.

    Study DesignProspective clinical study.ObjectiveComputer-assisted surgery (CAS) means improved accuracy in inserting screws. Usually the required time of the intraoperative use of a C-arm device is reduced. The aim of the study was to quantify the radiation doses during spine surgery in different types of computer-assisted surgical procedures (i.e., computerized tomography [CT] based and C-arm) compared to standard methods and, as a new technique, the Iso-C3D C-arm (Siemens, GER).Summary Of Background DataA total of 38 individuals were enrolled in the study, including 8 who underwent standard spine surgery, 10 with CT-based, 9 with C-arm based, and 11 with Iso-C3D C-arm based. The thermoluminescence dosimetry measurements were 2 at the radiation source, 2 at the patient, and 2 at the receiver.MethodsThis study is based on the thermoluminescence method. A total of 38 individuals were enrolled in the study. Despite the small number of patients, the existing results up until now showed a clear reduction of the duration of radiation time using CAS compared to standard methods in spine surgery. Much more important is the fact that the radiation doses were clearly reduced from a median of 1091 mGy using the standard procedure versus 432 mGy in CT-based and 664 mGy in C-arm based guided surgery. The Iso-C3D C-arm showed a median of 152 mGy.ResultsThe duration of radiation was reduced from 177 seconds in the standard spine procedure to 75 seconds in CT-based CAS spine intervention. Comparing the different types of CAS application at the spine, the Iso-C3D C-arm based surgery is the method with the lowest duration of radiation. The radiation doses at the C-arm tube (source) are reduced from a median of 1091 mGy in the standard procedure versus 432 mGy in CT-based and 664 mGy in C-arm based guided surgery. In this study, the median dose of an Iso-C3D C-arm was 152 mGy.ConclusionThese findings are important for the operating room personnel, which is exposed daily to radiation intraoperatively, as well as the patients, when using CAS procedures.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

Want more great medical articles?

Keep up to date with a free trial of metajournal, personalized for your practice.
1,694,794 articles already indexed!

We guarantee your privacy. Your email address will not be shared.