• J. Vasc. Surg. · Sep 2008

    Multicenter Study Controlled Clinical Trial

    Pivotal results of the Medtronic Vascular Talent Thoracic Stent Graft System: the VALOR trial.

    • Ronald M Fairman, Frank Criado, Mark Farber, Christopher Kwolek, Manish Mehta, Rodney White, Anthony Lee, J Michael Tuchek, and VALOR Investigators.
    • Hospital of the University of Pennsylvania, Philadelphia, PA, USA. ron.fairman@uphs.upenn.edu
    • J. Vasc. Surg. 2008 Sep 1;48(3):546-54.

    ObjectiveThis report summarizes the 30-day and 12-month results of endovascular treatment using the Medtronic Vascular Talent Thoracic Stent Graft System (Medtronic Vascular, Santa Rosa, Calif) for patients with thoracic aortic aneurysms (TAA) who are considered candidates for open surgical repair.MethodsThe study was a prospective, nonrandomized, multicenter, pivotal trial conducted at 38 sites. Enrollment occurred between December 2003 and June 2005. Standard follow-up interval examinations were prescribed at 1 month, 6 months, 1 year, and annually thereafter. These endovascular results were compared with retrospective open surgical data from three centers of excellence.ResultsThe Evaluation of the Medtronic Vascular Talent Thoracic Stent Graft System for the Treatment of Thoracic Aortic Aneurysms (VALOR) trial enrolled 195 patients, and 189 were identified as retrospective open surgical subjects. Compared with the open surgery group, the VALOR test group had similar age and sex distributions, but had a smaller TAA size. Patients received a mean number of 2.7 +/- 1.3 stent graft components. The diameters of 25% of the proximal stent graft components implanted were <26 mm or >40 mm. Left subclavian artery revascularization was performed before the initial stent graft procedure in 5.2% of patients. Iliac conduits were used in 21.1% of patients. In 33.5% of patients, the bare spring segment of the most proximally implanted device was in zones 1 or 2 of the aortic arch. In 194 patients (99.5%), vessel access and stent graft deployment were successful at the intended site. The 30-day VALOR results included perioperative mortality, 2.1%; major adverse advents, 41%; incidence of paraplegia, 1.5%; paraparesis, 7.2%; and stroke, 3.6%. The 12-month VALOR results included all-cause mortality, 16.1%; aneurysm-related mortality, 3.1%; conversion to open surgery, 0.5%; target aneurysm rupture, 0.5%; stent graft migration >10 mm, 3.9%; endoleak (12.2%), stent graft patency, 100%; stable or decreasing aneurysm diameter, 91.5%; and loss of stent graft integrity, four patients. No deployment-related events or perforation of the aorta by a graft component occurred. The Talent Thoracic Stent Graft showed statistically superior performance with respect to acute procedural outcomes (P < .001), 30-day major adverse events (41% vs 84.4%, P < .001), perioperative mortality (2% vs 8%, P < .01), and 12-month aneurysm-related mortality (3.1% vs 11.6%, P < .002) vs open surgery.ConclusionsThe pivotal VALOR 12-month trial results demonstrate that the Medtronic Talent Thoracic Stent Graft System is a safe and effective endovascular therapy as an alternative to open surgery in patients with TAA who were considered candidates for open surgical repair.

      Pubmed     Free full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

What will the 'Medical Journal of You' look like?

Start your free 21 day trial now.

We guarantee your privacy. Your email address will not be shared.