• J Clin Monit · May 1996

    Magnetron-based inline microwave fluid warmer.

    • G L Gibby, S Lampotang, and N Gravenstein.
    • Department of Anesthesiology, University of Florida College of Medicine, Gainesville 32610-0254, USA.
    • J Clin Monit. 1996 May 1;12(3):271-6.

    ObjectiveTo develop an in-line microwave fluid warming system that eliminates the difficulties of uneven heating that are characteristic of batch-mode microwave fluid warmers.MethodsUsing a commercial microwave oven, we developed a method for warming fluid as it flowed through tubing along a defined path in the oven's cavity. Algorithms utilizing either proportional or adaptive control were used to control microwave heating cycles by varying the heating pulse-width during 3-second epochs. Methods of fluid entry and exit were devised to minimize microwave leakage. Heating performance was tested using icewater at multiple flow rates from 18 mL/min to 105 mL/min.ResultsIn all warming tests, the system achieved temperature control without exceeding the maximum temperature allowable based on American Association of Blood Banks requirements. The adaptive control maintained the set temperature, with peak-to-peak oscillations of 2 degrees C or less. Microwave leakage was below the commercially required limit for home microwave appliances.ConclusionsThe combination of proportional and adaptive control is successful in controlling the permanent magnet magnetron microwave energy to heat the icewater tested. The in-line microwave warmer has the potential to become a successful medical fluid warmer. More study is needed to determine the stability of the control system under clinical conditions, and to evaluate its utility for warming blood.

      Pubmed     Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…