Investigative radiology · May 2013
Comparative StudyEvaluation of feasibility and image quality of 68Ga-DOTATOC positron emission tomography/magnetic resonance in comparison with positron emission tomography/computed tomography in patients with neuroendocrine tumors.
- Florian C Gaertner, Ambros J Beer, Michael Souvatzoglou, Matthias Eiber, Sebastian Fürst, Sybille I Ziegler, Florian Brohl, Markus Schwaiger, and Klemens Scheidhauer.
- Department of Nuclear Medicine, Technische Universitaet Muenchen, Klinikum rechts der Isar, Muenchen, Germany. florian.gaertner@tum.de
- Invest Radiol. 2013 May 1;48(5):263-72.
ObjectivesThe primary aims of this study were to evaluate the feasibility of simultaneous 68(DOTA(0)-Phe(1)-Tyr(3))octreotide positron emission tomography (PET)/magnetic resonance (MR) acquisition on a fully integrated PET/MR scanner in patients and to compare the quality of PET images acquired with a PET/MR device with those acquired with a PET/computed tomography (CT) scanner.Patients And MethodsSequential PET/CT and PET/MR imaging was performed in 24 patients with neuroendocrine tumors using a single-injection/dual-imaging protocol. After intravenous injection of 68Ga-DOTATOC (mean, 120 MBq), PET/CT imaging including low-dose CT was performed at a mean time of 17 minutes post injection, and subsequently, PET/MR imaging including a Dixon sequence for attenuation correction was started at a mean time of 82 minutes post injection. The PET/CT and PET/MR images were analyzed visually using a 4-point scale for quality, coregistration, anatomical correlation, and lesion conspicuity. The standardized uptake value of background organs and focal lesions was measured and compared between the PET/CT and PET/MR acquisitions.Results68Ga-DOTATOC PET acquired on the PET/MR delivered images with a good diagnostic quality (average visual rating PET/CT, 2.83; PET/MR, 2.08; P <; 0.01). The standardized uptake value of focal lesions did not differ between the PET/CT and PET/MR acquisitions (P >; 0.3) and correlated in a linear fashion (correlation coefficient ρ = 0.90). Lesion conspicuity was slightly, but significantly, higher on the PET/CT acquisitions (PET/CT, 2.71; PET/MR, 2.62; P = 0.01). Positron emission tomography/MR detected 153 of 157 lesions identified by PET/CT; however, there was no difference in sensitivity on a patient basis or organ system basis. Anatomical correlates for focal PET lesions could significantly more often be delineated using MR Dixon images compared with low-dose CT (average visual rating PET/CT, 1.78; PET/MR, 2.30; P <; 0.01). Coregistration of functional and morphological data was better on PET/MR compared with PET/CT, which, however, did not reach significance (average visual rating PET/CT, 2.17; PET/MR, 2.46; P = 0.10).Conclusions68Ga-DOTATOC PET/MR imaging is feasible in patients, with good image quality, and detectability of focal PET lesions was equivalent to PET/CT on a patient basis and organ system basis. Now, the clinical value of 68Ga-DOTATOC PET/MR with additional diagnostic MR protocols has to be evaluated against PET/CT with multiphase contrast-enhanced CT protocols in future studies.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.