-
J Cardiovasc Med (Hagerstown) · Mar 2013
Comparative StudyEchocardiography-guided versus fluoroscopy-guided temporary pacing in the emergency setting: an observational study.
- Francesco Pinneri, Simone Frea, Kamal Najd, Silvana Panella, Erica Franco, Valentina Conti, and Giuditta Corgnati.
- Division of Cardiology, Internal Medicine Department, Ospedale Civico di Chivasso, Italy. pinnerif@libero.it
- J Cardiovasc Med (Hagerstown). 2013 Mar 1;14(3):242-6.
BackgroundThe insertion of a temporary pacemaker can be a lifesaving procedure in the emergency setting.ObjectivesThis is an observational monocentric study comparing echocardiography-guided temporary pacemaker via the right internal jugular vein to standard fluoroscopy-guided temporary pacemaker via the femoral vein; the procedure was tested for noninferiority.MethodsPatients needing urgent pacing were consecutively enrolled. Primary efficacy endpoints were time to pacing and need for catheter replacement. Primary safety endpoint was a composite outcome of overall complications.ResultsOne hundred and six patients (77 ± 10 years) were enrolled: 53 underwent echocardiographic-guided and 53 fluoroscopy-guided temporary pacemaker. Baseline characteristics of the two groups of treatment were similar. Time to pacing was shorter in the echocardiography-guided than in the fluoroscopy-guided group (439 ± 179 vs. 716 ± 235 s; P<0.0001; power 100%). During the pacing (54 ± 35 h), there was a higher incidence of pacemaker malfunction in the fluoroscopy-guided group [15 vs. 3 patients; odds ratio (OR) 6.5, confidence interval (CI) 95% 1.9-29.7, P<0.001; power 5.7%] and there was a significantly lower incidence of complications in the echocardiography-guided temporary pacemaker group (6 vs. 22 patients; OR 0.18, CI 95% 0.06-0.49, P<0.001; echocardiography-guided temporary pacemaker events rate 0.1929 vs. fluoroscopy-guided temporary pacemaker events rate 1.398 per 100 person-hours paced, P<0.0001). In the standard group there was one death attributable to a temporary pacemaker complication (sepsis).ConclusionEchocardiography-guided temporary pacemaker is a well-tolerated procedure that could allow reliable insertion of a temporary pacemaker; therefore, it is a well-tolerated option in an emergency setting and in hospitals where fluoroscopy is not available.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.