Timing of pressure release affects power of breathing and minute ventilation during airway pressure release ventilation.
- C Putensen, M A León, and G Putensen-Himmer.
- Department of Anesthesiology, University of South Florida College of Medicine, Tampa 33612-4799.
- Crit. Care Med. 1994 May 1;22(5):872-8.
ObjectivesTo evaluate the effects of interference between spontaneous and mechanical breaths on the power of breathing (rate at which work is done) and ventilatory support during airway pressure release ventilation.DesignMultitrial tests under simulated clinical conditions using a mechanical respiratory system model.SettingA research laboratory at a university medical center.InterventionsSimulated spontaneous breathing augmented with continuous positive airway pressure and airway pressure release ventilation. Variation in synchrony between spontaneous breathing and mechanical ventilation was accomplished by adjusting the time lag between detection of the spontaneous inspiration and the airway pressure release from 0 to 3 secs in increments of 0.25 secs.Measurements And Main ResultsPressures and volumes were measured at the inlet of the lung and chest wall compartment of the respiratory system model. Pressure and volume changes measured at the inlet of the chest wall compartment were used to generate pressure/volume loops and to calculate the power of the spontaneous breathing. Minute ventilation was greater (p < .01) during all airway pressure release ventilation settings compared with those values of continuous positive airway pressure. Nonconflicting airway pressure release ventilation was associated with a higher minute ventilation (p < .001) than asynchronous airway pressure release ventilation. When spontaneous inspiration was synchronous with restoration of continuous positive airway pressure, minute ventilation was lower (p < .001) than during nonconflicting airway pressure release ventilation settings. Power of spontaneous breathing was highest when airway pressure release and spontaneous inspiration coincided, and lowest when spontaneous inspiration and restoration of continuous positive airway pressure were synchronized. Power of breathing was significantly lower during nonconflicting than during asynchronous airway pressure release ventilation (p < .01). No difference was observed between the power of spontaneous breathing and airway pressure release ventilation either with spontaneous expiration synchronized with airway pressure release or with nonconflicting airway pressure release ventilation. When calculated per liter of ventilation, power of spontaneous breathing was significantly lower (p < .01) during all airway pressure release ventilation settings compared with continuous positive airway pressure.ConclusionAsynchronous airway pressure release may increase the power of spontaneous breathing and reduce effective mechanical ventilatory support during airway pressure release ventilation. A clinical study is required to assess the effect of synchronous and asynchronous interference between spontaneous and mechanical breaths during airway pressure release ventilation.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.