    Assessment of lower limb alignment: supine fluoroscopy compared with a standing full-length radiograph.

    • Sanjeev Sabharwal and Caixia Zhao.
    • Department of Orthopedics, University of Medicine and Dentistry of New Jersey-New Jersey Medical School, Doctor's Office Center, 90 Bergen Street, Suite 7300, Newark, NJ 07103, USA. sabharsa@umdnj.edu
    • J Bone Joint Surg Am. 2008 Jan 1;90(1):43-51.

    BackgroundWhile a full-length standing anteroposterior radiograph of the lower extremity provides the best radiographic method for assessing limb alignment, other methods must be used intraoperatively. We have employed intraoperative fluoroscopy with use of an electrocautery cord to assess limb alignment in the supine patient.MethodsWe retrospectively compared the measurements of lower limb alignment that were obtained with use of supine intraoperative fluoroscopy with those that were obtained with use of a full-length standing anteroposterior radiograph of the lower extremity. A single examiner compared 102 sets of supine fluoroscopy images and full-length standing anteroposterior radiographs of the lower extremity to assess mechanical axis deviation and the joint line convergence angle. For the intraoperative fluoroscopic examination, an electrocautery cord was positioned overlying the center of the femoral head and the tibial plafond and an anteroposterior radiograph of the knee was made. The effect of age, gender, diagnosis, body mass index, pelvic height difference, joint line convergence angle, and the magnitude and direction of malalignment (varus or valgus) on the discrepancy in the observed mechanical axis deviation with use of the two methods was assessed.ResultsThe mean absolute difference between the two techniques was 13.4 mm for the measurement of mechanical axis deviation (p < 0.0001) and 2.8 degrees for the joint line convergence angle (p < 0.0001). The correlation coefficient (r) for the measurement of mechanical axis deviation with use of the two radiographic methods was 0.88. An increase in body mass index was associated with a greater magnitude of discrepancy in the measurement of mechanical axis deviation between the two techniques (p = 0.0014). Age, gender, pelvic height difference, and the direction of malalignment had no effect on the discrepancy in the measurement of mechanical axis deviation. Limbs with >2 cm of mechanical axis deviation and those with a joint line convergence angle of >3 degrees on the standing radiograph were significantly more likely to have >10 mm of discrepancy in the measurement of mechanical axis deviation with use of the two imaging techniques (p < 0.005).ConclusionsIntraoperative fluoroscopy with use of the electrocautery cord method is a useful tool for assessing lower limb alignment in patients with a normal body mass index and

      Pubmed     Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…