    Effect of selective aortic arch perfusion on median frequency and peak amplitude of ventricular fibrillation in a canine model.

    • C Barton, J E Manning, and N Batson.
    • Department of Emergency Medicine, University of North Carolina-Chapel Hill, USA.
    • Ann Emerg Med. 1996 May 1;27(5):610-6.

    Study ObjectiveTo determine whether the computer-derived measures of median frequency or peak amplitude of ventricular fibrillation (VF), obtained by fast Fourier transform of the VF waveform, change during selective aortic arch perfusion in a canine model of cardiac arrest.MethodsEight mongrel dogs (including 4 control animals) were sedated, intubated, catheterized, and instrumented to record the electrocardiogram (digitally at 100 Hz, filtered with a finite impulse response filter at 2 Hz), right atrial pressure, and aortic pressure during resuscitation in a model of VF-induced cardiac arrest. After 10 minutes of VF-induced arrest, cardiopulmonary resuscitation (CPR) with a mechanical chest compression device was initiated. Beginning 2 minutes later, the 4 study animals received, every 2 minutes, 45 seconds of selective aortic arch perfusion (SAAP) with autologous blood infusions under high pressure. Defibrillation was attempted after 3 minutes of CPR and every minute thereafter. Both study and control groups received standard-dose epinephrine (.01 mg/kg) every 3 minutes by means of an intraaortic catheter. The median frequency, peak amplitude, and coronary perfusion pressure (CPP) during the 5-second period just before defibrillation were obtained with the use of computer algorithms.ResultsAll SAAP animals and 1 control animal were resuscitated. Baseline measures of median frequency (8.4 +/- 1.5 versus 6.6 +/- 1.0 Hz) and peak amplitude (.18 +/- .05 versus .36 +/- .13 mV) were not different between the SAAP and control groups, respectively, at the start of CRP. SAAP infusion resulted in significant increases in the SAAP group compared with the control group: median frequency, 9.6 +/- .4 versus 7.3 +/- 1.4 Hz; peak amplitude, .74 +/- .21 versus .39 +/- .15 mV; and CPP, 40.5 +/- 7.1 versus 18.0 +/- 15.0 mm Hg, respectively. Median frequency correlated with CPP (r2 = .67). Peak amplitude did not correlate with CPP (r2 = .06).ConclusionMedian frequency and peak amplitude increase with SAAP during cardiac arrest in a canine model. This method of resuscitation was reliable in allowing restoration of a stable perfusing rhythm after defibrillation. Changes in measures of peak amplitude and median frequency may reflect interventions that enhance the likelihood of successful defibrillation and may thereby offer a noninvasive means of monitoring interventions during cardiac arrest.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

Want more great medical articles?

Keep up to date with a free trial of metajournal, personalized for your practice.
1,694,794 articles already indexed!

We guarantee your privacy. Your email address will not be shared.