• Interact Cardiovasc Thorac Surg · Jun 2007

    Case Reports

    The 'aortic rim' recount: embolization of interatrial septal occluder into the main pulmonary artery bifurcation after atrial septal defect closure.

    • Manoranjan Misra, Adil Sadiq, Narayanan Namboodiri, and Jayakumar Karunakaran.
    • Department of Cardio-Vascular and Thoracic Surgery, Sree Chitra Tirunal Institute for Medical Sciences and Technology, Trivandrum, Kerala, India-695 011. ranjan@sctimst.ac.in
    • Interact Cardiovasc Thorac Surg. 2007 Jun 1;6(3):384-6.

    IntroductionPercutaneous device closure of atrial septal defect (ASD) has emerged as an alternative to traditional surgical closure. Although reduced hospital stay, decreased morbidity and absence of a surgical incision are beneficial, other procedure- or device-related complications are coming into light. We report a rare complication of early embolization of the Blockaid septal occluder into the main pulmonary artery bifurcation associated with 'aortic rim' erosion and present a brief review of literature pertaining to the high incidence of complications associated with deficient or eroded 'aortic rims' necessitating surgical intervention.Materials And MethodsAn 18-year-old male underwent successful percutaneous device closure of a 24.5 mm ASD after fulfilling institutional criteria for the procedure. The device used was a Blockaid septal occluder, a device morphologically similar to the Amplatzer device. The subsequent day, he had embolization of the device into the main pulmonary artery bifurcation, and underwent emergency surgical retrieval of the same with closure of the ASD. At surgery the ASD was found to have an eroded aortic rim.CommentsWe believe that embolization of the percutaneous septal occluder in our patient was due to a combination of factors including an inadequate aortic rim; a grossly oversized device which eroded the aortic rim; and the Blockaid septal occluder, whose formally untested design and configuration could have led to its migration.ConclusionStrict selection criteria governing an 'adequate' aortic rim, the size of the device, and the choice of the device may help reduce the incidence of complications like the rare, but potentially fatal embolization of the device into the pulmonary artery following percutaneous device closure of an ASD.

      Pubmed     Free full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…