Comparative Study
Cardiac output measurement by pulse dye densitometry in cardiac surgery.
- W Baulig, E O Bernhard, D Bettex, D Schmidlin, and E R Schmid.
- Division of Cardiovascular Anaesthesia, University Hospital of Zürich, Rämistrasse 100, 8091 Zürich, Switzerland. werner.Baulig@usz.ch
- Anaesthesia. 2005 Oct 1;60(10):968-73.
AbstractSummary The aim of this study was to compare the accuracy of pulse dye densitometry with that of bolus thermodilution cardiac output measurement in patients before and after elective coronary artery bypass grafting. Twenty-eight patients were studied. Agreement between mean thermodilution and pulse dye densitometry cardiac output values was assessed by Bland-Altman analysis. Preoperative median [range] cardiac output was 3.87 [2.37-6.0] l.min(-1) by thermodilution, and 3.11 [1.7-5.45] l.min(-1) by pulse dye densitometry using indocyanine green 5 mg. Pulse dye densitometry underestimated cardiac output (mean bias - 0.42 l.min(-1)); the limits of agreement were +/- 1.91 l.min(-1), and mean error was 50.3%, indicating low precision. Preoperative median [range] cardiac output was 3.85 [2.2-6.0] l.min(-1) for bolus thermodilution cardiac output and 4.2 [2.0-7.2] l.min(-1) for pulse dye densitometry using indocyanine green 20 mg. Mean bias was + 0.566 l.min(-1), the limits of agreement were +/- 2.51 l.min(-1) and mean error was 60.9%. Postoperative cardiac output data were not analysed because pulse dye densitometry signals were low or absent in > 50% of the patients. We conclude that pulse dye densitometry using indocyanine green 5 mg or 20 mg is inaccurate in anaesthetised patients before coronary artery bypass surgery and cannot be used after surgery because of a high incidence of low pulse dye densitometry signal amplitudes.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.