• Eur J Cardiothorac Surg · Jul 1998

    Non-invasive measurement of cardiac output during coronary artery bypass grafting.

    • A J Cohen, D Arnaudov, D Zabeeda, L Schultheis, J Lashinger, and A Schachner.
    • Department of Cardiovascular Surgery, The Edith Wolfson Medical Center, Holon, Israel.
    • Eur J Cardiothorac Surg. 1998 Jul 1;14(1):64-9.

    ObjectiveA new device, using whole body bioresistance measurements and a new equation for calculating stroke volume has been developed. Using this equation, an attempt was made to correlate whole body bioresistance cardiac output with thermodilution cardiac output in patients undergoing coronary artery bypass grafting.MethodsThirty-one adults undergoing elective coronary artery bypass grafting were studied prospectively. Simultaneous paired cardiac output measurements by whole body bioresistance and thermodilution were made at five time points during coronary artery bypass grafting: in anesthetized patients before incision (T1), after sternotomy (T2), after opening the pericardium (T3), ten min post bypass (T4), and in the intensive care unit (T5). The patients had a mean of three thermodilution cardiac outputs compared with a mean of three bioimpedance measurements at each time point. The bias and precision between the methods were calculated.ResultsThere was good correlation between bioresistance cardiac output (nCO) and thermodilution cardiac output (ThCO) measurements in both groups for all recorded times. The patients' mean ThCO and nCO, as well as bias and precision between methods were calculated. Mean ThCO ranged between 4.14 and 5.06 l/min; mean nCO ranged between 4.12 and 4.97 l/ min. Bias calculations ranged between -0.072 and 0.104 l/min. Precision (2 SD) calculations ranged between 0.873 and 1.228 l/min for 95% confidence intervals. Pearson's correlation ranged from 0.919 to 0.938.ConclusionsCardiac output measured with the new device correlates well with the thermodilution measurements of cardiac output during and immediately following coronary artery bypass grafting. The overall agreement between the two methods was good. The new device is an accurate non-invasive method of measuring cardiac output during coronary artery bypass grafting.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…