• Academic radiology · Aug 2013

    Diagnostic performance evaluation of a computer-aided simple triage system for coronary CT angiography in patients with intermediate risk for acute coronary syndrome.

    • Mathias Meyer, U Joseph Schoepf, Christian Fink, Roman Goldenberg, Paul Apfaltrer, Joachim Gruettner, Diana Vajcs, Stefan O Schoenberg, and Thomas Henzler.
    • Department of Clinical Radiology and Nuclear Medicine, University Medical Center Mannheim, Medical Faculty Mannheim-Heidelberg University, Theodor-Kutzer-Ufer 1-3, D-68167 Mannheim, Germany. mr.meyer.mathi... more as@gmail.com less
    • Acad Radiol. 2013 Aug 1;20(8):980-6.

    Rationale And ObjectivesGiven the significance of coronary artery disease as the most important socioeconomic health care problem in the Western World, the application of computer-aided simple triage (CAST) systems to this disease would be desirable.Materials And MethodsIn total, 93 patients with acute chest pain and an intermediate risk score for acute coronary syndrome underwent coronary computed tomography angiography (cCTA). Among those, 74 were of adequate image quality for automated analysis by a commercially available CAST system (COR Analyzer, RCADIA, Haifa, Israel). CAST findings were compared to human expert interpretation for the detection of significant stenosis (≥50%) in the left main, left anterior descending, circumflex, right coronary artery, or arterial branches. Further, one inexperienced observer evaluated all studies for significant stenoses alone and after 1 month guided by a CAST system as an initial read.ResultsHuman expert interpretation identified 37/74 patients with stenosis ≥50%, whereas the CAST detected 45 patients. The CAST system demonstrated a sensitivity of 100%/79% and a specificity of 78%/89% on a per-patient/per-vessel level, respectively. With CAST, the inexperienced readers' per-vessel sensitivity and positive predictive values significantly improved (P = .011, P = .009) from 69% and 41% to 91% and 74%, respectively.ConclusionsThe investigated CAST system for automatic stenosis detection can accurately identify patients with coronary artery stenosis ≥50% and may be of use as initial interpretation and triage of cCTA studies as well as a second reader for inexperienced readers, in absence of expert readers.Copyright © 2013 AUR. Published by Elsevier Inc. All rights reserved.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        

    hide…