• J. Am. Coll. Cardiol. · Dec 1998

    Comparative Study

    Variation of anatomic valve area during ejection in patients with valvular aortic stenosis evaluated by two-dimensional echocardiographic planimetry: comparison with traditional Doppler data.

    • M Arsenault, N Masani, G Magni, J Yao, L Deras, and N Pandian.
    • Non-invasive Cardiac Imaging Laboratory, Tufts University, New England Medical Center, Boston, Massachusetts, USA. marie.arsenault@hopitallaval.qc.ca
    • J. Am. Coll. Cardiol. 1998 Dec 1;32(7):1931-7.

    ObjectivesFlow variations can affect valve-area calculation in aortic stenosis and lead to inaccuracies in the evaluation of the stenosis. Knowing that transvalvular flow varies normally within one beat, we designed this study to assess the response of the valve to intrabeat variation of flow during systole. Results were compared with flow-derived measurements.BackgroundTechnological improvements now allow us to evaluate aortic valve area directly by short axis planimetry. This offers the possibility to perform serial planimetries during one ejection phase and analyze the intrabeat dynamic behavior of the stenotic-aortic valve and compare these measurements with flow-derived measurements.MethodsForty echocardiograms displaying different degrees of aortic stenosis were analyzed by frame-by-frame planimetry of the valve area from onset of opening to complete closure. Maximal-mean area, opening and closing rates and ejection times were obtained and compared with Doppler-derived data.ResultsValve area varied during ejection. Stenotic valves opened and closed more slowly than normals and remained maximally open for a shorter period. Mean area by Doppler data corresponded more closely to maximal than to mean-planimetered area. Duration of flow was shorter than valve opening in severely stenotic valves. Discrepancies between Doppler-derived and two-dimensional (2D) measurements decreased in less stenotic valves.ConclusionsOur observations reveal striking differences between the dynamics of normal and stenotic valves. Surprisingly, Doppler-derived mean-valve area correlated better with maximal-anatomic area than with mean-anatomic area in patients with aortic stenosis. Discrepancies between duration of flow and valve opening could explain this phenomenon.

      Pubmed     Free full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…