• Br J Anaesth · Jun 2014

    Feasibility and accuracy of nasal alar pulse oximetry.

    • T E Morey, M J Rice, T Vasilopoulos, D M Dennis, and R J Melker.
    • Department of Anesthesiology, University of Florida, PO 100254, 1600 SW Archer Road, Gainesville, FL 32601-0254, USA morey@ufl.edu.
    • Br J Anaesth. 2014 Jun 1;112(6):1109-14.

    BackgroundThe nasal ala is an attractive site for pulse oximetry because of perfusion by branches of the external and internal carotid arteries. We evaluated the accuracy of a novel pulse oximetry sensor custom designed for the nasal ala.MethodsAfter IRB approval, healthy non-smoking subjects [n=12; aged 28 (23-41) yr; 6M/6F] breathed hypoxic mixtures of fresh gas by a facemask to achieve oxyhaemoglobin saturations of 70-100% measured by traditional co-oximetry from radial artery samples. Concurrent alar and finger pulse oximetry values were measured using probes designed for these sites. Data were analysed using the Bland-Altman method for multiple observations per subject.ResultsBias, precision, and accuracy root mean square error (ARMS) over a range of 70-100% were significantly better for the alar probe compared with a standard finger probe. The mean bias for the alar and finger probes was 0.73% and 1.90% (P<0.001), respectively, with corresponding precision values of 1.65 and 1.83 (P=0.015) and ARMS values of 1.78% and 2.72% (P=0.047). The coefficients of determination were 0.96 and 0.96 for the alar and finger probes, respectively. The within/between-subject variation for the alar and finger probes were 1.14/1.57% and 1.87/1.47%, respectively. The limits of agreement were 3.96/-2.50% and 5.48/-1.68% for the alar and finger probes, respectively.ConclusionsNasal alar pulse oximetry is feasible and demonstrates accurate pulse oximetry values over a range of 70-100%. The alar probe demonstrated greater accuracy compared with a conventional finger pulse oximeter.© The Author [2014]. Published by Oxford University Press on behalf of the British Journal of Anaesthesia. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

      Pubmed     Free full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

What will the 'Medical Journal of You' look like?

Start your free 21 day trial now.

We guarantee your privacy. Your email address will not be shared.