• Can J Anaesth · Jun 2003

    Case Reports

    Failure to provide adequate one-lung ventilation with a conventional endotracheal tube using a transbronchial approach: a case report.

    • Yuet Tong Ng, Peter Chi Ho Chung, Jing Ru Hsieh, Chun Cheung Yu, Wai Meng Lau, and Yun Hen Liu.
    • Department of Anesthesiology, Chang Gung Memorial Hospital at Keelung, Keelung, Taiwan.
    • Can J Anaesth. 2003 Jun 1;50(6):603-6.

    PurposeTo report a case where failure to provide adequate one-lung ventilation during transbronchial intubation resulted in a potentially fatal mishap.Clinical FeaturesA 61-yr-old male was scheduled for right lung lobectomy. Induction of general anesthesia was smooth, and subsequent resection of the right middle lobe was uneventful. Difficult ventilation with high airway pressure and poor right lung re-expansion prompted repositioning of the double-lumen tube after the resection. The removal of the right middle bronchial clamp and associated right mainstem manipulation caused flooding of blood into the double-lumen tube. Mindful of the risk of fatal desaturation, the surgeon immediately opened the right mainstem bronchus and cleared the airway. Confirmation of a displaced double-lumen tube prompted the surgeon to insert an endotracheal tube (internal diameter 5.5 mm) from the opened right mainstem bronchus to the left main bronchus to maintain oxygenation. Although bronchoscopic examination confirmed proper location of the reinserted tube, oxygen saturation was not sufficiently (60%) improved. Another 5.5-mm endotracheal tube was inserted, with its tip inside the right upper bronchiole, for further ventilatory support. Finally, a rise in SpO2 to around 95% allowed completion of surgery.ConclusionsDisplacement of the double-lumen endobronchial tube and flooding with clotted blood will result in potentially fatal ventilation difficulties. Repositioning and cleaning of the tube must be prompt to reduce the risk of hypoxemia. Where emergency single-lung ventilation is required, we suggest the utilization of a modified single-lumen endotracheal tube with a shortened cuff-tip length to ensure an adequate margin of safety for mainstem bronchus intubation.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

Want more great medical articles?

Keep up to date with a free trial of metajournal, personalized for your practice.
1,694,794 articles already indexed!

We guarantee your privacy. Your email address will not be shared.