-
- M Jaeger, T Ashbury, M Adams, and P Duncan.
- Department of Anaesthesia, Queen's University, Kingston, Ontario.
- Can J Anaesth. 1996 Aug 1;43(8):795-8.
PurposeThis study assessed the accuracy of photometer based haemoglobin (Hb) determination technology (HemoCue) when used by different anaesthetists in situations of rapidly changing Hb values during anaesthesia.Methods(Part 1) In the laboratory, repeated measurements were done on 16 split samples of blood using both the Hematology Analyzer (CELL-DYN 3500 System, Abbot Laboratories, San Jose, California) and the photometer. (Part 2) Twelve patients had blood samples drawn from an arterial line for simultaneous Hb determination in the hospital laboratory and by the photometer. At the same time, capillary samples were taken from the patient's earlobe for Hb determination by the photometer. All sample collection and photometer measurements were done by the same operator. (Part 3) The Part 2 protocol was then repeated with different anaesthetists performing both the sampling and the photometer measurements. Statistical comparison was by ANOVA and a two-tailed paired t-test.Results(Part 1) Samples determined by the photometer and the laboratory were highly correlated (r2 = 1.0, P < 0.001). The average error of each method was similar ( < 4%). (Part 2) Using a 2-tailed paired t-test, the photometer arterial measurements were not different from the laboratory measurements, however the photometer capillary measurements were consistently approximately 8% higher (P = 0.003). (Part 3) When multiple operators performed the sampling there were no differences on arterial or capillary samples (r2 = 0.942, r2 = 0.851 respectively), although the variance was greater.ConclusionsThe HemoCue haemoglobinometer has sufficient accuracy to support treatment decisions regarding blood transfusions.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.