    Automatic detection of chest compressions for the assessment of CPR-quality parameters.

    • U Ayala, T Eftestøl, E Alonso, U Irusta, E Aramendi, S Wali, and J Kramer-Johansen.
    • Department of Electrical Engineering and Computer Science, Faculty of Science and Technology, University of Stavanger, 4036 Stavanger, Norway; Communications Engineering Department, University of the Basque Country UPV/EHU, Alameda Urquijo S/N, 48013 Bilbao, Spain. Electronic address: unai.ayala@ehu.es.
    • Resuscitation. 2014 Jul 1;85(7):957-63.

    AimAccurate chest compression detection is key to evaluate cardiopulmonary resuscitation (CPR) quality. Two automatic compression detectors were developed, for the compression depth (CD), and for the thoracic impedance (TI). The objective was to evaluate their accuracy for compression detection and for CPR quality assessment.MethodsCompressions were manually annotated using the force and ECG in 38 out-of-hospital resuscitation episodes, comprising 869 min and 67,402 compressions. Compressions were detected using a negative peak detector for the CD. For the TI, an adaptive peak detector based on the amplitude and duration of TI fluctuations was used. Chest compression rate (CC-rate) and chest compression fraction (CCF) were calculated for the episodes and for every minute within each episode. CC-rate for rescuer feedback was calculated every 8 consecutive compressions.ResultsThe sensitivity and positive predictive value were 98.4% and 99.8% using CD, and 94.2% and 97.4% using TI. The mean CCF and CC-rate obtained from both detectors showed no significant differences with those obtained from the annotations (P>0.6). The Bland-Altman analysis showed acceptable 95% limits of agreement between the annotations and the detectors for the per-minute CCF, per-minute CC-rate, and CC-rate for feedback. For the detector based on TI, only 3.7% of CC-rate feedbacks had an error larger than 5%.ConclusionAutomatic compression detectors based on the CD and TI signals are very accurate. In most cases, episode review could safely rely on these detectors without resorting to manual review. Automatic feedback on rate can be accurately done using the impedance channel.Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…