• Spine J · Nov 2013

    Fluoroscopically guided anterior atlantoaxial transarticular screws: a feasibility and trajectory study using CT-based simulation software.

    • Mary R A Padua, Jin S Yeom, So Y Lee, So M Lee, Ho-Joong Kim, Bong-Soon Chang, Choon-Ki Lee, and K Daniel Riew.
    • Spine Center and Department of Orthopaedic Surgery, Seoul National University College of Medicine and Seoul National University Bundang Hospital, 166 Gumiro, Bundang-ku, Sungnam 463-707, Republic of Korea.
    • Spine J. 2013 Nov 1;13(11):1455-63.

    Background ContextAnterior transarticular screw (ATAS) fixation has been suggested as a viable alternative to posterior stabilization. However, we are not aware of previous reports attempting to establish the usefulness of specific fluoroscopic landmark-guided trajectories in the use of ATAS, and we could find no reference to it in a computerized search using MEDLINE.PurposeTo determine the anatomic feasibility of ATAS placement using defined fluoroscopic landmarks to guide screw trajectory.Study DesignEvaluation using three-dimensional screw insertion simulation software and 1.0-mm-interval computed tomographic scans.Patient SampleComputed tomographic scans of 100 patients including 50 men and 50 women.Outcome MeasuresIncidence of violation of the vertebral artery groove of C1 and C2, the spinal canal, and the atlanto-occipital joint and screw lengths and lengths of C1 and C2 purchase.MethodsFour screw trajectories were determined: promontory screw (PS), single central facet (CF) screw, and medial (MF) and lateral (LF) double facet screws. Placement of a 4.0-mm screw was simulated using defined fluoroscopic landmarks for each trajectory. The previously mentioned outcome measures were evaluated and compared for the four trajectories. This study was not supported by any financial sources, and there is no topic-specific potential conflict of interest with this study.ResultsNo violation of the C1 or C2 vertebral artery groove or of the spinal canal was observed for any of the screw types. Screw lengths and the length of C2 purchase were by far the longest for PS (40.4±2.8 and 25.7±2.1 mm, respectively; p<.001 in all post hoc comparisons). The length of C1 purchase was longer for CF (16.4±2.3 mm) and LF (15.8±1.6 mm) than PS (14.7±2.0 mm) and MF (14.6±2.4 mm) (p≤.001, respectively). There was no atlanto-occipital joint violation if the length of C1 purchase was set at 12 mm for CF and LF and at 10 mm for PS and MF.ConclusionsOur results suggest that it may be possible to place ATASs without violating the vertebral artery groove, spinal canal, or the atlanto-occipital joint by using the described entry points, trajectories, and fluoroscopic landmarks.Copyright © 2013 Elsevier Inc. All rights reserved.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

What will the 'Medical Journal of You' look like?

Start your free 21 day trial now.

We guarantee your privacy. Your email address will not be shared.