• American heart journal · Jun 1995

    Comparative Study

    Hemodynamic importance of preserving the normal sequence of ventricular activation in permanent cardiac pacing.

    • C Leclercq, D Gras, A Le Helloco, L Nicol, P Mabo, and C Daubert.
    • Department of Cardiology, Hotel Dieu/Centre Hospitalier, Rennes, France.
    • Am. Heart J. 1995 Jun 1;129(6):1133-41.

    AbstractPacing the right ventricle in the apex profoundly modifies the sequence of activation and thus the sequence of contraction and relaxation of the left ventricle. To evaluate the relative importance of preserving normal ventricular activation sequence and optimal atrioventricular (AV) synchrony in permanent pacing, we compared the effects of three pacing modes: AAI, preserving both normal AV synchrony and normal activation sequence; DDD, with complete ventricular capture that preserves only AV synchrony; and VVI, disrupting both, at rest and during exercise. Hemodynamic and radionuclide studies were performed in 11 patients who had normal intrinsic conduction and who were implanted on a long-term basis with a DDDR pacemaker for isolated sinus node dysfunction. AAI versus DDD and VVI significantly increased cardiac output at rest (6.6 +/- 1.3 L/min vs 6 +/- 0.9 L/min vs 5 +/- 1 L/min; p < 0.01) and during exercise (13.5 +/- 2 L/min vs 12.1 +/- 2.2 L/min vs 14.4 +/- 2.1 L/min; p < 0.01). Pulmonary capillary wedge pressure was lowest with AAI (15.4 +/- 4.5 mm Hg), with an average reduction of 17% compared with DDD (19.6 +/- 5 mm Hg; p < 0.01) and of 30% compared with VVI (25.8 +/- 7 mm Hg; p < 0.01) during exercise. Identical benefits were observed for all other hemodynamic parameters: right atrial pressure, pulmonary artery pressure, left ventricular (LV) stroke work index, and systemic vascular resistances. LV ejection fraction was significantly higher in AAI than in DDD at rest (61% vs 58%, respectively; p < 0.05) and during exercise (65% vs 60%, respectively; p < 0.05). This improvement in LV systolic function resulted principally from the increase in septal ejection fraction. LV filling also was improved in AAI as demonstrated by a significant increase in peak filling rate at rest and during exercise. These data show the importance of preserving, whenever possible, not only normal AV synchrony but also normal ventricular activation sequence in permanent cardiac pacing.

      Pubmed     Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

What will the 'Medical Journal of You' look like?

Start your free 21 day trial now.

We guarantee your privacy. Your email address will not be shared.