-
Pacing Clin Electrophysiol · Jun 2007
Electromagnetic Interference (EMI) and arrhythmic events in ICD patients undergoing gastrointestinal procedures.
- Danette Guertin, Osman Faheem, Thea Ling, Glenn Pelletier, David McComas, Ravi K Yarlagadda, Christopher Clyne, and Jeffrey Kluger.
- Section of Heart Rhythm Management, Henry Low Heart Center, Hartford Hospital, Hartford, Connecticut 06102, USA.
- Pacing Clin Electrophysiol. 2007 Jun 1;30(6):734-9.
BackgroundThe objective was to determine the effect of electromagnetic interference (EMI) in patients undergoing gastrointestinal endoscopy. The implantable cardioverter-defibrillator (ICD) is the primary therapeutic modality for patients at risk for sudden cardiac death. One potential problem with ICDs is interactions with electrical devices and medical procedures causing EMI or triggering arrhythmic events. Endoscopy frequently employs electrocautery (EC) for diagnosis and treatment of gastrointestinal diseases. Current guidelines advise inactivating ICDs before any surgical procedure. There is limited information on management of ICDs during endoscopy with or without EC. We prospectively evaluated patients with ICDs undergoing endoscopic procedures at our institution.Methods And ResultsForty-one ICD patients underwent 52 gastrointestinal endoscopies over 17 months. The mean age of the population was 66 years (51-83). There were 28 men and 13 women. Thirteen patients had single chamber devices, 25 had dual chamber devices, and 2 had biventricular ICDs. The mean tachyarrhythmia detection rate programmed was 164.7 bpm (125-188). Eighteen procedures (43.9%) required biopsy, coagulation, or polypectomy. Of these, 10 (55%) required the use of EC. Only unipolar EC with mean current 19.6 mA was used. All ICDs were programmed to detection-only with therapies off. Sensitivity was left at nominal programmed settings. Post procedure interrogation showed no detection of EMI or tachyarrhythmic events.ConclusionsOur study shows no EMI or arrhythmic events triggered during endoscopic procedures in patients with pectorally implanted transvenous ICDs. Routine practice of programming ICDs off for gastrointestinal procedures may not be necessary. However, larger studies are needed before change in current recommendations.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.