• Vet Anaesth Analg · Mar 2015

    Challenges of thermal nociceptive threshold testing in the donkey.

    • Nicola J Grint, Helen R Whay, Thierry Beths, Kathy Yvorchuk, and Joanna C Murrell.
    • Ross University School of Veterinary Medicine, St Kitts, West Indies; Animal Welfare and Behaviour Group, University of Bristol, Bristol, UK.
    • Vet Anaesth Analg. 2015 Mar 1;42(2):205-14.

    ObjectiveTo evaluate a thermal nociceptive threshold (TNT) testing device in the donkey, and the influence of potential confounding factors on TNTs.AnimalsTwo groups (Group 1 and Group 2) of eight castrated male donkeys aged 4-9 years, weighing 105-170 kg.MethodsTNTs were measured by heating a thermal probe on skin until an end-point behaviour (threshold temperature) or a cut-out temperature (51 °C) was reached. The withers and the dorsal aspect of the distal limb were used as sites for TNT testing. The effects on TNT of different confounding factors: the limb tested; rate of heating; and ambient temperature were evaluated. Data were analyzed using general linear models, and Mann-Whitney tests, p < 0.05 was considered significant.ResultsEnd-point behaviours (skin twitch or donkey looking at test device) when the thermal probe heated the withers were observed in approximately half of tests. TNT was (mean ± SD) 46.8 ± 2.85 °C. Subsequently the limb was evaluated as the test site in Group 1 followed by Group 2 donkeys; end-point behaviour being a foot-lift. In Group 1, 72% of tests ended in an end-point behaviour but the response rate was lower in Group 2 (20%), although TNTs were similar [(47.6 ± 3.3) and (47.3 ± 3.0) °C respectively] for responding animals. Rate of heating, ambient temperature and laterality (right or left) did not affect thresholds, but mean TNT was significantly higher in the forelimb (48.5 ± 2.8 °C) than the hind limb (47.4 ± 2.8 °C) (p = 0.012).ConclusionsWhen a thermal probe cut-out temperature of 51 °C was used in TNT testing in the donkey a high proportion of tests did not produce an identifiable end point behaviour. Higher cut-out temperatures damaged the skin. Under these conditions, thermal nociceptive threshold testing appears not be an appropriate analgesiometry technique in the donkey.Clinical RelevanceTNT testing under these conditions is not suitable form of analgesiometry for donkeys.© 2014 Association of Veterinary Anaesthetists and the American College of Veterinary Anesthesia and Analgesia.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

What will the 'Medical Journal of You' look like?

Start your free 21 day trial now.

We guarantee your privacy. Your email address will not be shared.