-
Anesthesia and analgesia · Sep 2014
In Vitro Evaluation of a Novel System for Monitoring Surgical Hemoglobin Loss.
- Gerhardt Konig, Allen A Holmes, Rosario Garcia, Julianne M Mendoza, Mazyar Javidroozi, Siddarth Satish, and Jonathan H Waters.
- From the Department of Anesthesiology, University of Pittsburgh Medical Center, Pittsburgh, Pennsylvania; †Department of Anesthesiology and Perioperative Medicine, MD Anderson Cancer Center, Houston, Texas; ‡Department of Anesthesia, Stanford University School of Medicine, Palo Alto, California; §Department of Anesthesiology, Critical Care, and Hyperbaric Medicine, Englewood Hospital and Medical Center, Englewood, New Jersey; ‖Division of Research & Development, Gauss Surgical, Inc., Palo Alto, California; ¶Departments of Anesthesiology and Bioengineering, University of Pittsburgh School of Medicine; and #McGowan Institute for Regenerative Medicine, University of Pittsburgh, Pittsburgh, Pennsylvania.
- Anesth. Analg. 2014 Sep 1; 119 (3): 595-600.
BackgroundAccurate measurement of intraoperative blood loss is an important clinical variable in managing fluid resuscitation and avoiding unnecessary transfusion of blood products. In this study, we measured surgical blood loss using a tablet computer programmed with a unique algorithm modeled after facial recognition technology. The aim of the study was to assess the accuracy and performance of the system on surgical laparotomy sponges in vitro.MethodsWhole blood samples of premeasured hemoglobin (Hb) and volume were reconstituted from units of human packed red blood cells and plasma and distributed across surgical laparotomy sponges. Normal saline was added to simulate the presence of varying levels of hemodilution and/or irrigation use. Soaked sponges from 4 different manufacturers were scanned using the Triton System with Feature Extraction Technology (Gauss Surgical, Inc., Palo Alto, CA) under 3 different ambient light conditions in an operating room. Accuracy of Hb loss measurement was evaluated relative to the premeasured values using linear regression and Bland-Altman analysis. Correlations between studied variables and measurement bias were analyzed using nonparametric tests.ResultsThe overall mean percent error for measure of Hb loss for the Triton System was 12.3% (95% confidence interval [CI], 8.2%-16.4%). A strong positive linear correlation between the premeasured and actual Hb masses was noted across the full range of intraoperative lighting conditions, including (A) high (r = 0.95 [95% CI, 0.93-0.96]), (B) medium (r = 0.94 [95% CI, 0.93-0.96]), and (C) low (r = 0.90 [95% CI, 0.87-0.93]) mean ambient light intensity. Bland-Altman analysis revealed a bias of 0.01 g [95% CI, -0.03 to 0.06 g] of Hb per sponge between the 2 measures. The corresponding lower and upper limits of agreement were -1.16 g (95% CI, -1.21 to -1.12 g) per sponge and 1.19 g (95% CI, 1.15-1.24 g) per sponge, respectively. Measurement bias of estimated blood loss and Hb mass using the new system were not associated with the volume of saline used to reconstitute the samples (P = 0.506 and P = 0.469, respectively), suggesting that the system is robust under a wide range of sponge saturation conditions.ConclusionsMobile blood loss monitoring using the Triton system is accurate in assessing Hb mass on surgical sponges across a range of ambient light conditions, sponge saturation, saline contamination, and initial blood Hb. Utilization of this tool could significantly improve the accuracy of blood loss estimates.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.