• J Orthop Trauma · Aug 2000

    Comparative Study

    Evaluation of a new method of small fragment fixation in a medial malleolus fracture model.

    • D Rovinsky, A Haskell, Q Liu, G D Paiement, and S Robinovitch.
    • Department of Orthopaedic Surgery, University of California, San Francisco, USA.
    • J Orthop Trauma. 2000 Aug 1;14(6):420-5.

    ObjectiveTo evaluate a new method of small fragment fixation in a medial malleolus fracture model.Design/MethodsThe authors measured the pullout strength, resistance to shear stress, and speed of insertion of 4.0-millimeter partially threaded cancellous screws, 2.4-millimeter smooth K-wires, and a small fragment fixation system with 2.2-millimeter threaded K-wires. Pullout strength was tested in eighty-one synthetic foam blocks and resistance to shear stress in thirty synthetic tibias by use of a servohydraulic testing machine. Six randomized time trials with the threaded K-wires and cancellous screws were also conducted.ResultsPullout strength increased with increasing foam density, increasing insertion depth, and varied with fixation method (p < 0.05). Maximum pullout strengths were as follows: partially threaded cancellous screws, 730+/-4 Newtons; threaded K-wires, 316+/-12 Newtons; and smooth K-wires, 172 +/-5 Newtons. Percent difference in pullout strength between the partially threaded cancellous screw and threaded K-wire diminished with increased depth of insertion and increased foam density. Offset axial load to initiate fracture displacement in a synthetic tibia model averaged 1540+/-138 Newtons for the partially threaded cancellous screws, 1,318+/-117 Newtons for the threaded K-wires, and 1,287+/-121 Newtons for the smooth K-wires (p > 0.05). Average time of fixation of a medial malleolar fragment by orthopedic surgeons with a variety of experience levels in a synthetic tibia with two threaded K-wires (114+/-8 seconds) was significantly faster (p < 0.05) than with two partially threaded cancellous screws (207+/-20 seconds).ConclusionsThreaded K-wires show substantial pullout strength and similar resistance to offset axial load when compared with partially threaded cancellous screws. These threaded K-wires offer an alternative for the internal fixation of medial malleolus fractures.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

What will the 'Medical Journal of You' look like?

Start your free 21 day trial now.

We guarantee your privacy. Your email address will not be shared.