• Ann Emerg Med · Jul 1993

    Randomized Controlled Trial Clinical Trial

    Effect of needle changing and intravenous cannula collection on blood culture contamination rates.

    • D Smart, C Baggoley, J Head, D Noble, B Wetherall, and D L Gordon.
    • Department of Emergency Medicine, Flinders Medical Centre, Bedford Park, South Australia.
    • Ann Emerg Med. 1993 Jul 1;22(7):1164-8.

    Study ObjectivesWe tested the hypotheses that blood culture positivity and contamination rates were not increased by not changing needles between venipuncture and inoculation of blood culture bottles or by taking blood for culture by freshly inserted IV cannulae.DesignA prospective study of blood cultures collected by venipuncture or IV cannulae taken from an emergency department population. Venipuncture samples were randomized into needle change (standard method) or no needle change before inoculation into blood culture bottles.ParticipantsNine hundred forty patients requiring blood cultures after assessment in the ED.InterventionsA standard disinfection procedure using 0.5% chlorhexidine in 70% alcohol was used. Blood was collected by venipuncture and inoculated with or without needle change. Blood collected by IV cannula was inoculated with a fresh needle applied to the collection syringe.Measurements And Main ResultsThere was no statistically significant difference in contamination rates for blood collected by venipuncture with no needle change (6.4%) compared with needle change (4.2%, P > .30). No significant difference in contamination rates was noted for blood taken by freshly inserted IV cannulae (4.3%) compared with venipuncture with needle change after sampling (4.2%, P > .90). Some problems with randomization resulted in unequal numbers in the needle-change (286) versus no-needle-change (141) subgroups, and this may have introduced bias. A higher rate of pathogen growth was observed in blood taken by IV cannula (11.4%) compared with the standard method (6.3%) (P < .025). A significantly greater rate of Gram-negative sepsis was noted in the IV cannula group (6.6%) compared with direct venipuncture with needle change (1.1%) and no needle change (4.2%, P < .01).ConclusionThe results of this study do not support the practice of changing needles before inoculating blood samples into blood culture bottles. Collection of blood for culture through freshly inserted IV cannulae is associated with a low contamination rate and is an acceptable alternative to direct venipuncture. Sources of bias in this study suggest that further research is needed to determine the optimal technique for collecting blood cultures.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…