Multicenter Study Clinical Trial
Atrial septal defect occlusion with the buttoned device (a multi-institutional U.S. trial).
- T R Lloyd, P S Rao, R H Beekman, A M Mendelsohn, and E B Sideris.
- Steele Memorial Children's Research Center, University of Arizona, Tucson.
- Am. J. Cardiol. 1994 Feb 1;73(4):286-91.
AbstractA clinical trial was conducted of the buttoned device for transcatheter closure of ostium secundum atrial septal defect. Occlusion was attempted in 57 patients aged 1 to 62 years (median 5). The procedure was abandoned in 7 patients after 1 or more unsuccessful attempts, and devices were released in 50 patients. Urgent surgical retrieval was necessary in 4 patients because of unstable device position: 3 devices "unbuttoned," with migration of the counteroccluder to the pulmonary artery or inferior vena cava, and 1 intact device embolized to the main pulmonary artery. All patients remained stable and underwent successful operation. Successful device implantation was therefore achieved in 46 patients, with immediate reduction in Qp/Qs from 1.8 +/- 0.6 to 1.1 +/- 0.2 (mean +/- SD, p < 0.0001). At most recent follow-up (1 to 20 months), 45 of 46 patients (98%) have no shunt or a trivial residual shunt. The prevalence of residual shunts declined from 65% at 1 month to 19% at 12 months after the occlusion procedure (p < 0.0001). Complications included unbuttoning of a fourth device, transient tricuspid regurgitation in 2 patients, and transient mitral regurgitation in 2 patients. An episode of asymptomatic atrial flutter was noted in a 46-year-old patient which may have been related to device implantation, but which has not recurred. There have been no cases of endocarditis or thromboembolism in 350 patient-months of follow-up. The buttoned device provided effective closure of the atrial septal defect in 45 of 57 patients (79%) in whom implantation was attempted and in 45 of 46 patients (98%) in whom device implantation was successfully accomplished.(ABSTRACT TRUNCATED AT 250 WORDS)
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.