• Ophthalmology · Feb 1999

    Comparative Study

    Agreement and repeatability of infrared pupillometry and the comparison method.

    • B S Wachler and R R Krueger.
    • Department of Ophthalmology, Jules Stein Eye Institute, UCLA School of Medicine, USA.
    • Ophthalmology. 1999 Feb 1;106(2):319-23.

    ObjectiveTo evaluate the accuracy and repeatability of the widely used comparison method of measuring pupil size.DesignCross-sectional study.ParticipantsFourteen eyes of seven healthy myopic subjects were examined.InterventionTwo examiners made two repeated measures of pupil diameters of 14 eyes using Rosenbaum card comparison pupillometry and infrared pupillometry. Subjects fixated on a distant visual acuity chart, and pupils were measured under three luminance conditions. The agreement and inter-rater repeatability of both methods were determined.Main Outcome MeasuresOutcomes were pupil diameters, limits of agreement, and coefficient of repeatability of two examiners.ResultsThe mean difference between the two techniques ranged from 0.3 to 0.5 mm. The limits of agreement within two standard deviations ranged from 2.4 to 2.8 mm. Coefficient of repeatability ranged from 0.6 to 1.4 mm for infrared pupillometry and 1.0 to 1.2 mm for Rosenbaum pupillometry. Inter-rater repeatability of Rosenbaum pupillometry was consistently pupil diameter biased. Pupil diameters measured with the Rosenbaum method were consistently larger than diameters measured with the infrared technique for both examiners under all luminance conditions.ConclusionsResults indicate that although the mean difference in techniques was small, the range of the agreement between the Rosenbaum and the infrared techniques was large. The Rosenbaum method consistently overestimated pupil diameters and was subject to inter-rater repeatability bias. Rosenbaum pupillometry may not be appropriate when accurate pupil measurements are required. The results have implications for many clinical trials in ophthalmology, including those evaluating refractive surgery that use Rosenbaum comparison pupillometry.

      Pubmed     Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

What will the 'Medical Journal of You' look like?

Start your free 21 day trial now.

We guarantee your privacy. Your email address will not be shared.