• J Clin Monit Comput · Aug 2009

    Model fitting of volumetric capnograms improves calculations of airway dead space and slope of phase III.

    • Gerardo Tusman, Adriana Scandurra, Stephan H Böhm, Fernando Suarez-Sipmann, and Fernando Clara.
    • Department of Anesthesiology, Hospital Privado de Comunidad, Mar del Plata, Argentina. gtusman@hotmail.com
    • J Clin Monit Comput. 2009 Aug 1;23(4):197-206.

    BackgroundThis study assessed the performance of a Functional Approximation based on a Levenberg-Marquardt Algorithm (FA-LMA) to calculate airway dead space (VD(aw)) and the slope of phase III (S(III)) from capnograms.MethodsWe performed mathematical simulations to test the effect of noises on the calculation of VD(aw) and S(III). Data from ten mechanically ventilated patients at 0, 5 and 10 cmH(2)O of PEEP were also studied. FA-LMA was compared with the traditional Fowler's method (FM).ResultsSimulations showed that: (1) The FM determined VD(aw) with accuracy only if the capnogram approximated a symmetrical curve (S(III) = 0). When capnograms became asymmetrical (S(III) > 0), the FM underestimated VD(aw) (-3.1% to -0.9%). (2) When adding noises on 800 capnograms, VD(aw) was underestimated whenever the FM was used thereby creating a bias between -5.54 and -1.28 ml at standard deviations (SD) of 0.1-1.8 ml (P < 0.0001). FA-LMA calculations of VD(aw) were close to the simulated values with the bias ranging from -0.21 to 0.16 ml at SD from 0.1 to 0.4 ml. The FM overestimated S(III) and showed more bias (0.0041-0.0078 mmHg/ml, P < 0.0001) than the FA-LMA (0.0002-0.0030 mmHg/ml). When calculating VD(aw) from patients, variability was less with the FA-LMA leading to mean variation coefficients of 0.0102, 0.0111 and 0.0123 compared to the FM (0.0243, 0.0247 and 0.0262, P < 0.001) for 0, 5 and 10 cmH(2)O of PEEP, respectively. The FA-LMA also showed less variability in S(III) with mean variation coefficients of 0.0739, 0.0662 and 0.0730 compared to the FM (0.1379, 0.1208 and 0.1246, P < 0.001) for 0, 5 and 10 cmH(2)O of PEEP, respectively.ConclusionsThe Functional Approximation based on a Levenberg-Marquardt Algorithm showed less bias and dispersion compared to the traditional Fowler's method when calculating VD(aw) and S(III).

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…