-
Anesthesia and analgesia · May 2016
Analysis of Transpulmonary Thermodilution Data Confirms the Influence of Renal Replacement Therapy on Thermodilution Hemodynamic Measurements.
- Sven Schmidt, Timm Westhoff, Peter Schlattmann, Walter Zidek, and Friederike Compton.
- From the *Department of Nephrology, Charité University Medicine Berlin, Campus Benjamin Franklin, Berlin, Germany; †Department of Medicine I, Universitätsklinikum Marien Hospital Herne, Ruhr-Universität Bochum, Herne, Germany; and ‡Department of Medical Statistics, Informatics and Documentaton, Jena University Hospital, Jena, Germany.
- Anesth. Analg. 2016 May 1; 122 (5): 1474-9.
BackgroundTranspulmonary thermodilution (TPTD) is used frequently in the intensive care unit to determine cardiac index (CI), intrathoracic blood volume index (ITBVI), and extravascular lung volume index (EVLWI). Renal replacement therapy (RRT) influences TPTD results, but the underlying mechanisms are not completely understood. We hypothesized that RRT blood flow induces errors in TPTD measurements.MethodsWe analyzed TPTD data available from the PiCCO® plus hemodynamic measurement device on a personal computer using a proprietary Pulsion Medical Systems software. By using the dialysis catheter to inject the thermal indicator, 20 measurement series were performed in 12 intensive care unit patients determining CI, ITBVI, and EVLWI during RRT with the blood pump stopped, and at flows of 100 and 200 mL/min, respectively.ResultsData export was successful in 17 measurement series and showed a significant decrease in measured CI (6.5 ± 2.5 vs 5.4 ± 1.9 L/min/m, P < 0.001) and ITBVI (1358.8 ± 274.5 vs 1132.8 ± 218.3 mL/m, P < 0.001) with RRT and a significant increase in EVLWI (8.6 ± 4.4, 10.2 ± 4.5 mL/kg, P < 0.001). Blood temperature before and the temperature decrease after injection of the thermal indicator were unchanged by RRT. Mean transit time and downslope time of the thermodilution curve, however, were both increased with the RRT blood pump running (P ≤ 0.001).ConclusionsAnalysis of TPTD data shows that thermodilution curve forms are modified with RRT, resulting in an erroneous calculation of thermodilution-derived hemodynamic parameters.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.