• Anesthesia and analgesia · Jan 2010

    Closed-circuit xenon delivery using a standard anesthesia workstation.

    • Shilpa Rawat and John Dingley.
    • Department of Anaesthetics and Intensive Care Medicine, Morriston Hospital, Swansea SA6 6NL, UK.
    • Anesth. Analg. 2010 Jan 1;110(1):101-9.

    BackgroundXenon (Xe) is an anesthetic with minimal side effects, now also showing promise as a neuroprotectant both in vitro and in vivo. Although scarce and expensive, Xe is insoluble and patient uptake is low, making closed circuits the optimum delivery method. Although the future of Xe anesthesia is uncertain, effective neuroprotection is highly desirable even if moderately expensive. A factor limiting Xe research in all these fields may be the perceived need to purchase special Xe anesthesia workstations that are expensive and difficult to service. We investigated the practicality of 1) true closed-circuit Xe delivery using an unmodified anesthesia workstation with gas monitoring/delivery attachments restricted to breathing hoses only, 2) a Xe delivery protocol designed to eliminate wastage, and 3) recovering Xe from exhaled gas.MethodsSixteen ASA physical status I/II patients were recruited for surgery of > 2 h. Denitrogenation with 100% oxygen was started during induction and tracheal intubation under propofol/remifentanil anesthesia. This continued after operating room transfer for 30 min. All fresh gases were then temporarily stopped, metabolic oxygen consumption then being replaced with 250-mL Xe boluses until F(I)Xe = 50%. A basal oxygen fresh gas flow was thereafter restored with additional Xe given as required via the expiratory hose to maintain a F(I)Xe > or = 50%. At no time, apart from during circle flushes every 90 min, were the bellows allowed to completely fill and spill gas, ensuring the circle remained closed. On termination of anesthesia, the first 10 exhaled breaths were collected as was residual gas from the circle, allowing measurement of the Xe content of each.ResultsTotal Xe consumption, including initial wash-in and circle flushes, was 12.62 (5.31) L or 4.95 (0.82) L/h, mean (sd). However, consumption during maintenance periods was lower: 3 L/h at 1 h and 2 L/h thereafter. Of the total Xe used, 8.98% (5.94%) could be recovered at the end of the procedure.ConclusionsWe report that closed-circuit Xe delivery can be achieved with a modified standard anesthesia workstation with breathing hose alterations only and that the protocol was very gas efficient, especially during the normally wasteful Xe wash-in. A Xe mixture of > or = 50% was delivered for up to 341 min (5 h 41 min) and Xe consumption was 4.95 (0.82) L/h, maintenance being achieved with 2-3 L/h. With this degree of efficiency, Xe recovery/recycling at the end of anesthesia may be of little additional benefit.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

Want more great medical articles?

Keep up to date with a free trial of metajournal, personalized for your practice.
1,694,794 articles already indexed!

We guarantee your privacy. Your email address will not be shared.