-
- A Breakell and C Townsend-Rose.
- The Royal Liverpool University Hospital, The Accident and Emergency Department, Liverpool, UK. andybreak@compuserve.com
- Resuscitation. 2001 Aug 1;50(2):185-7.
AbstractThe difficulties inherent in the 'Look, Listen and Feel' method of identifying respiratory arrest prompted the authors to develop a simple mechanical breathing indicator that can show clearly, at a glance, whether or not a patient is breathing. The novel indicator was designed to be highly visible so that its interpretation should be obvious to medical personnel and the lay public, and yet sufficiently simple so that it could be easily and inexpensively incorporated into the type of pocket rescue masks currently in use. The indicator needs no power source, works indoors and outdoors and does not interfere with the delivery of rescue breaths during resuscitation. A prototype of the improved pocket mask incorporating the new indicator was made and was tested for its ability to detect breaths over a range of inspiratory flow rates and inspiratory pressures. The authors found that the indicator responded to peak inspiratory flow rates of between 15 and 120 l/min, inspiratory pressures as low as 0.18 cm H(2)O with no supplemental oxygen flowing to the mask and 0.22 cm H(2)O with supplemental oxygen flowing at 9 l/min, minute ventilation volumes between 7.1 and 21.8 l/min, tidal volumes between 0.36 and 2.92 l and a respiratory rate range of 7-24 breaths per min. The authors conclude that the new indicator, when attached to a pocket rescue mask, is sensitive enough to identify clearly and reliably those patients at the scene of collapse who have stopped breathing. Additionally it may assist rescuers in timing the delivery of assisted rescue breaths in those patients with poor respiratory effort.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.