• Eur Spine J · Nov 2016

    Influence of lower limbs discrepancy and pelvic coronal rotation on pelvic incidence, pelvic tilt and sacral slope.

    • Piotr Janusz, Marcin Tyrakowski, Monsef Jad Bou JB Department of Orthopaedic Surgery, University of Illinois at Chicago, 835 South Wolcott Ave, Room E-270, Chicago, IL, 60612, USA., and Kris Siemionow.
    • Department of Orthopaedic Surgery, University of Illinois at Chicago, 835 South Wolcott Ave, Room E-270, Chicago, IL, 60612, USA. mdpjanusz@gmail.com.
    • Eur Spine J. 2016 Nov 1; 25 (11): 3622-3629.

    PurposePelvic incidence (PI), pelvic tilt (PT) and sacral slope (SS) are important parameters in sagittal spine alignment evaluation. The measurements are a projection of the three-dimensional pelvis onto a two-dimensional radiograph and they may be influenced by orientation of the pelvis. The aim of this study was to assess the influence of pelvic rotation in the coronal plane (CPR) on radiographic accuracy of PI, PT, and SS measurements.MethodsRadiological evaluation of the CPR angel was performed on 1 radiological phantom. The radiographs were taken in 5° CPR increments over a range of 0°-45° (evaluated with a digital protractor). On each of the lateral radiograph, PI, PT, and SS were measured three times by three independent researchers. The lowest CPR that changed PI, PT, or SS by ≥6° (the highest reported error of measurement of these parameters) was considered as unacceptable. Next, CPR was calculated based on the distance between femoral heads (FHD). The agreement of the calculated and measured CPR was quantified by the intraclass correlation coefficient (ICC) and the median error for a single measurement (SEM), with value 0.75 considered as excellent agreement.ResultsPI, PT and SS could be measured with an acceptable error of 6° on radiographs with up to 20° pelvic rotation. From 20° CPR onwards the S1 endplate was distorted, that makes the measurements of PI, PT and SS questionable. There was an excellent agreement between CPR measured with a protractor and calculated based on FHD with ICC of 0.99 and SEM of 1.1°.ConclusionsRotation of the pelvis in the coronal plane during acquisition of radiographs influences PI, PT and SS measurements. Substantial error of PI, PT and SS measurements occurs with CPR of more than 20° which is equivalent to a lower limb discrepancy of 5.2 cm. CPR may be calculated while acquiring the radiograph. Further evaluation of the influence of CPR on spinopelvic parameters with a larger sample would be valuable.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…