• Clin J Pain · Sep 2004

    Comparative Study

    Reproducibility indices applied to cervical pressure pain threshold measurements in healthy subjects.

    • Tamara Prushansky, Zeevi Dvir, and Ruth Defrin-Assa.
    • Department of Physical Therapy, Sackler Faculty of Medicine, Tel Aviv University, Ramat Aviv, Israel. zdvir@post.tau.ac.il
    • Clin J Pain. 2004 Sep 1; 20 (5): 341-7.

    ObjectivesTo apply various statistical indices for reproducibility analysis of pressure pain threshold measurements and to derive a preferred pressure pain threshold measurement protocol based on these indices.MethodsThe pressure pain threshold of 3 pairs of right and left homologous cervical region sites were measured in 20 healthy subjects (10 women, 10 men) using a hand-held pressure algometer. Measurements took place on 2 occasions (test 1 and test 2) separated by a mean interval of 1 week. On each testing session, the site-related pressure pain thresholds were measured 3 times each according to 2 different protocols. Protocol A consisted of a repetitive order, namely 3 consecutive measurements at each site before proceeding to the next, whereas protocol B consisted of an alternate order in which 3 consecutive rounds of all individually tested sites took place. For test 1, protocol A was followed by protocol B with an hour interval. For test 2, the reverse order took place.ResultsThe findings revealed no significant differences between the two protocols and indicated a significant rise (P < 0.0001) in the absolute scores from test 1 to test 2 in both protocols. Absolute values (mean +/-SD) derived from the entire sample of pressure pain threshold sites ranged from 140 +/- 60 to 198.7 +/- 95 kPa (1.60 +/- 0.6 to 1.99 +/- 0.95 kg/cm, respectively). No significant gender or side differences were noted. Pearson r as well as the intraclass correlation coefficient revealed good to excellent reproducibility for both protocols and for all sites measured: r = 0.79-0.94 and intraclass correlation coefficient(3,3) = 0.85-0.96, respectively. To define site-specific cutoff values indicating change at the 95% confidence level, 1.96*SEM was calculated, and its values ranged from 31.6 to 58.2 kPa, which correspond to 16.8% to 32.8% of the absolute mean values. In addition, the limits of agreement, which depict the individual test-retest differences relative to their mean, indicated a heteroscedastic trend.DiscussionThe two protocols yielded very similar results. However, on the grounds of patient's comfort and compliance as well as facility of application, protocol B stands out as the more preferred between the two.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…