-
- A S Cesario, P Palermo, D Baragli, E Amici, G Biancalana, G Gambelli, and R Neri.
- Divisione di Cardiologia, Ospedale G.B. Grassi, Roma.
- G Ital Cardiol. 1998 Aug 1;28(8):878-86.
BackgroundPotentially lethal interactions between concomitantly implanted pacemaker and automatic first-generation cardioverter-defibrillator have been reported. We therefore evaluated the reliability and safety of simultaneous implantation of dual-chamber pacemakers with a fourth generation cardioverter-defibrillator incorporating an improved arrhythmia detection system.MethodsConcomitant implantation of an automatic cardioverter defibrillator and a dual-chamber pacemaker was performed in four patients for malignant tachyarrhythmias and symptomatic bradycardia. Two Jewel 7219C and two Micro Jewel 7223 (Medtronic Inc.) implantable cardioverter defibrillators were connected to an endocardial lead (Medtronic Mod. 6936). In 2 patients with a previously implanted cardioverter-defibrillator, the pacemaker was connected to bipolar atrial and ventricular leads. In the 2 patients who already had a dual-chamber pacemaker, the unipolar pacing leads implanted previously were used. At the time of implantation of the second device, interaction testing was performed evaluating ventricular fibrillation detection during high-output asynchronous pacing. Testing for malfunctions, reprogramming or variations of pacing thresholds of the pacemakers after electric shocks was also carried out. Moreover, intracavitary signals, stimulation thresholds and electrical therapies delivered were evaluated during follow-up.ResultsDuring interaction testing, induced ventricular fibrillation was detected, with no delay, in 4/4 cases (100%). After a mean follow-up of 6.3 +/- 5 months (range 2-13), 5 shocks for ventricular fibrillation, 10 shocks for fast ventricular tachycardia and 72 antitachycardia pacings were delivered. All these electrical therapies were considered appropriate. No symptomatic sustained tachyarrhythmia remained undetected.ConclusionsThese data suggest that concomitant implantation of a fourth-generation automatic cardioverter-defibrillator and a dual-chamber pacemaker using either unipolar or bipolar leads can be performed safely. Extreme caution and rigorous interactions testing is nevertheless advised when considering this device combination.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.