Comparative Study
Ventilator-Integrated Jet Nebulization Systems: Tidal Volume Control and Efficiency of Synchronization.
- Stephan Ehrmann, Aissam Lyazidi, Bruno Louis, Daniel Isabey, Déborah Le Pennec, Laurent Brochard, and Gabriela Apiou-Sbirlea.
- Institut National de la Santé et de la Recherche Médicale, U955, Équipe Biomécanique Cellulaire et Respiratoire, and the Centre National de la Recherche Scientifique, équipe de recherche labellisée 7240, Créteil, France. Université Paris-Est Créteil, Unité Mixte de Recherche S955, Créteil, France. Service de Réanimation Polyvalente, Centre Hospitalier Régional Universitaire de Tours, Tours, France. Centre d'Étude des Pathologies Respiratoires, Institut National de la Santé et de la Recherche Médicale, UMR 1100/EA6305 F-37032 Tours, France, and the Faculté de Médecine de Tours, UMR 1100 Université François Rabelais, F-37032 Tours, France. stephanehrmann@gmail.com.
- Respir Care. 2014 Oct 1;59(10):1508-16.
BackgroundJet nebulizers constitute the aerosolization devices most frequently used during mechanical ventilation. Continuous nebulization can influence the delivered tidal volume (V(T)) and lead to significant medication loss during expiration. Ventilators thus provide integrated jet nebulization systems that are synchronized during inspiration and ostensibly keep VT constant.MethodsThis was a bench study of systems integrated in the Evita XL, Avea, Galileo, and G5 ventilators. The VT delivered with and without nebulization, the inspiratory synchronization of nebulization, and the aerosol deposition were measured with 2 locations of the nebulizer.ResultsChanges in V(T) with the nebulizer were below 20 mL and below 10% of set V(T) for all ventilators. Synchronization was good at the beginning of insufflation, but prolonged nebulization was observed with all ventilators at the end of insufflation, until up to 1 s during expiration: 5-80% of nebulization occurred during expiration with significant aerosol loss in the expiratory limb. Synchrony could be improved by (1) reducing gas compression/decompression phenomena proximal to the jet nebulizer and (2) increasing inspiratory time, which reduced the amount of nebulization occurring during expiration. Placing the nebulizer upstream in the inspiratory limb did not affect inspiratory synchrony but allowed reduction of the amount of aerosol lost in the expiratory limb.ConclusionsJet nebulizer systems integrated in the tested ventilators are reliable in terms of V(T) control. Gas compression in tubing driving gas to the nebulizer delays synchronization and reduces nebulization yield if the nebulizer is placed close to the Y-piece. Increasing inspiratory time with no end-inspiratory pause reduces the expiratory loss of medication if placement of the nebulizer upstream in the inspiratory limb is not feasible.Copyright © 2014 by Daedalus Enterprises.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.