    A comparative analysis of bench-top performance assessment of distal protection filters in transient flow conditions.

    • Gail M Siewiorek, Mark H Wholey, and Ender A Finol.
    • Institute for Complex Engineered Systems, Carnegie Mellon University, Pittsburgh, Pennsylvania, USA.
    • J. Endovasc. Ther. 2012 Apr 1;19(2):249-60.

    PurposeTo compare the performance in vitro of 6 distal protection filters (DPFs) on the basis of filtration ability and effects on pressure gradient and vascular impedance in a flow model of the internal carotid artery (ICA).MethodsSix DPFs (Accunet, Angioguard, FilterWire, Gore Embolic Filter, NAV6, and SpiderFX) were evaluated in a physiologically realistic flow loop. A blood analog was heated to body temperature and circulated by a pulsatile pump outputting a time-varying flow rate representative of the ICA. The ICA flow model was a highly curved tube representing a challenging site for filter deployment. The DPFs were deployed at the apex of the curved segment, and 2 sizes of microspheres (143 and 200 µm) were injected to simulate embolization. The capture efficiency, pressure gradient, normalized pressure gradient, and vascular impedance were calculated.ResultsThe Gore filter had high capture efficiency (143 µm: 99.97%; 200 µm: 100.00%) with relatively small increases in pressure gradient (143 µm: +27%; 200 µm: +20%) and vascular impedance (143 µm: +23.4%; 200 µm: +6.1%) after particles were injected. Spider had the lowest capture efficiency (143 µm: 1.50%; 200 µm: 19.34%, p<0.0005), while NAV6 (143 µm: +916%, p<0.0005) and Accunet (200 µm: +179%, p<0.0005) yielded the largest pressure gradient increases.ConclusionA bench-top flow apparatus exhibiting physiologically realistic conditions was developed by combining pulsatile flow and a body temperature blood analog. Using microspheres larger than the pore size of most of the DPFs, the device-wall apposition has an important effect on the overall filter performance and the global fluid dynamics in the flow model.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

Want more great medical articles?

Keep up to date with a free trial of metajournal, personalized for your practice.
1,694,794 articles already indexed!

We guarantee your privacy. Your email address will not be shared.