IEEE Trans Biomed Eng · May 2008
Estimation of the aortic pressure waveform and beat-to-beat relative cardiac output changes from multiple peripheral artery pressure waveforms.
- Gokul Swamy and Ramakrishna Mukkamala.
- Department of Electrical and Computer Engineering, Michigan State University, East Lansing, MI 48824, USA. swamygok@msu.edu
- IEEE Trans Biomed Eng. 2008 May 1;55(5):1521-9.
AbstractWe introduce a patient- and time-specific technique to estimate the clinically more relevant aortic pressure (AP) waveform and beat-to-beat relative changes in cardiac output (CO) from multiple peripheral artery pressure (PAP) waveforms distorted by wave reflections. The basic idea of the technique is to first estimate the AP waveform by applying a new multichannel blind system identification method that we have developed (rather than the conventional generalized transfer function) to the PAP waveforms and then estimate the beat-to-beat proportional CO by fitting a Windkessel model to the estimated waveform in which wave distortion should be attenuated. We present an evaluation of the technique with respect to four swine datasets including simultaneous measurements of two peripheral AP waveforms, a reference AP waveform, and reference aortic flow probe CO during diverse hemodynamic interventions. Our results show an overall AP waveform error of 3.5 mmHg and an overall beat-to-beat CO error of 12.9% (after a single CO calibration in each animal). These estimation errors represent substantial improvements compared to those obtained with several alternative PAP waveform analysis techniques. With further successful testing, the new technique may ultimately be employed for automated and less invasive monitoring of central hemodynamics in various cardiovascular patients.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.