• Arthroscopy · Jan 2007

    Glove tears during arthroscopic shoulder surgery using solid-core suture.

    • Kevin M Kaplan, Konrad I Gruson, Chris T Gorczynksi, Eric J Strauss, Fred J Kummer, and Andrew S Rokito.
    • Department of Orthopaedic Surgery, New York University Hospital for Joint Diseases, New York, New York 10003, USA. kaplak02@med.nyu.edu
    • Arthroscopy. 2007 Jan 1;23(1):51-6.

    PurposeSurgeons have noticed an increased incidence of finger lacerations associated with arthroscopic knot tying with solid-core suture material. This study examines glove perforations and finger lacerations during arthroscopic shoulder surgery.MethodsWe collected 400 surgical gloves from 50 consecutive arthroscopic shoulder repair procedures using No. 2 solid-core sutures. Two surgeons using double gloves were involved in every case, with one being responsible for tying all knots. Powder-free latex gloves were worn in all cases. Knots consisted of a sliding stitch of the surgeon's preference followed by 3 half-hitches via a knot-pusher instrument. All gloves were inspected grossly and then tested for tears with an electroconductivity meter.ResultsThe knot-tying surgeon had significantly more glove tears than the control (P < .01). Tears were localized to the radial side of the index finger of the glove at the distal interphalangeal joint in all cases. Of the tying surgeon's gloves, 68 (34%) were found to have tears. These included 17 inner gloves (17%) and 51 outer gloves (51%). If an inner glove was torn, the corresponding outer glove was torn in all cases. A mean of 3.96 knots were tied in each case. There was a significantly higher incidence of inner glove tears when more than 3 knots were tied (P < .03). There was no significant difference in glove tears between suture types. Finger lacerations did occur in the absence of glove tears. However, in the presence of an inner glove tear, there was a statistically significant association with a finger laceration at the corresponding level (P < .03).ConclusionsIntraoperative glove tears and subsequent finger lacerations occur with a high frequency when arthroscopic knots are tied with solid-core suture material. Risk can potentially be minimized by frequent glove changes or use of more durable, less penetrable gloves.Clinical RelevanceThis study addresses surgeon and patient safety during arthroscopic shoulder surgery.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…