• Anesthesia and analgesia · Sep 2014

    Assessment of Early Thromboelastometric Variables from Extrinsically Activated Assays With and Without Aprotinin for Rapid Detection of Fibrinolysis.

    • Daniel Dirkmann, Klaus Görlinger, and Jürgen Peters.
    • From the Klinik für Anästhesiologie und Intensivmedizin, Universität Duisburg-Essen, Universitätsklinikum Essen, Essen, Germany.
    • Anesth. Analg.. 2014 Sep 1;119(3):533-42.

    BackgroundAlthough thromboelastometry (ROTEM®) and thrombelastography can be used for bedside diagnosis of fibrinolysis, the time needed for detection is often prolonged. Since untreated fibrinolysis can result in consumption of coagulation factors and bleeding, early diagnosis and decision making are desirable. Accordingly, we assessed ROTEM variables from extrinsically activated assays with (APTEM) and without (EXTEM) addition of aprotinin for their ability to rapidly identify fibrinolysis. Specifically, we tested the hypotheses that prolonged clotting time, clot formation time, low clot firmness (at 5, 10, 15, and 20 minutes, designated A5, A10, A15, and A20, respectively), low maximum clot firmness (MCF) in EXTEM assays, and differences in these variables from parallel APTEM and EXTEM assays (designated as Δvariables) predict fibrinolysis.MethodsData from 411 thromboelastometric measurements (obtained from 352 patients) with fibrinolysis and from 2537 measurements without fibrinolysis (obtained from 1605 patients) were assessed and analyzed using receiver operating characteristics. Data were analyzed as a pooled fibrinolysis cohort, and subanalyses were performed from sets assigned to categories of fibrinolysis related to the timing of thrombus lysis (i.e., a decrease of clot firmness to <15% of MCF within 30, 45, and 60 minutes, respectively). A lower 95% confidence limit of the area under the receiver operating characteristic curve (AUC [SE] <0.6) was considered a failure to substantially improve detection of increased fibrinolysis. AUCs were compared to identify the variable providing the best predictive association with fibrinolysis. As a secondary end point, optimum cutoff values at the point estimate corresponding to the greatest Youden index were calculated along with the respective sensitivities and specificities.ResultsIn the pooled cohort, clot formation time (AUC: 0.652 [0.016]), α-angle (AUC: 0.675 [0.015]), A5 (AUC: 0.718 [0.013]), A10 (AUC: 0.734 [0.0.13]), A15 (AUC: 0.752 [0.013]), A20 (AUC: 0.771 [0.013]), and MCF (AUC: 0.799 [0.012]) predicted fibrinolysis. Fibrinolysis was also predicted by ΔA15 (AUC: 0.675 [0.016]), ΔA20 (AUC: 0.719 [0.015]), and ΔMCF (AUC: 0.812 [0.013]). AUCs increased in a time-related fashion. The ability to predict subsequent fibrinolysis based on thromboelastometry was higher when it occurred early rather than later during testing. However, for prediction of late fibrinolysis, only MCF (AUC: 0.655 [0.025]) appears to be potentially clinically useful.ConclusionsLow early values of clot firmness in extrinsically activated thromboelastometric assays are associated with fibrinolysis and improve its early detection. Additional assays with aprotinin fail to improve the early diagnosis of fibrinolysis compared with assays without aprotinin.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..