- L Badimon, V Turitto, J A Rosemark, J J Badimon, and V Fuster.
- Division of Cardiology, Mount Sinai School of Medicine, New York, NY 10029.
- J. Lab. Clin. Med. 1987 Dec 1;110(6):706-18.
AbstractA plastic (Plexiglas) chamber for evaluating platelet deposition under controlled hemodynamic conditions has been developed. The perfusion chamber has been designed to retain the cylindrical shape typical of the vasculature, to be flexible enough to accept a variety of biologic and prosthetic materials, and to simulate a broad range of physiologic flow conditions in either an ex vivo or in vitro perfusion system. Three type of surfaces were exposed to blood flowing directly from the carotid artery of a heparinized pig through the perfusion chamber: de-endothelialized pig aorta, collagen strips from rabbit Achilles tendon, and an expanded polytetrafluoroethylene material (Gore-Tex). Platelets, previously radiolabeled with indium 111 and injected into the animal, were quantified on the material surface, and the total number of deposited platelets determined for a range of blood flow rates (5 to 40 ml/min) and exposure times (0.5 to 20 minutes). The deposition rates were correlated with theory for describing the mass transport of platelets to the test surface. At the wall shear rates investigated (105 to 850 sec-1), the deposition of platelets on subendothelium was strongly dependent on the local flow conditions. Values of deposition on Gore-Tex obtained at similar flow conditions (105 to 425 sec-1) were reduced compared with that observed on subendothelium and showed a markedly weaker dependence on the shear rate. In contrast, deposition of platelets on collagen was more than an order of magnitude greater than on subendothelium and showed a dependence on flow only at the lowest flow rate studied (10 ml/min). The results indicate that collagen is much more reactive than subendothelium and Gore-Tex with respect to the growth and stability of platelet aggregates and moreover suggest that flow mechanisms for depositing platelets on various surface may be substantially different.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.