• J. Vasc. Surg. · May 2013

    Computer modeling for the prediction of thoracic aortic stent graft collapse.

    • Salvatore Pasta, Jae-Sung Cho, Onur Dur, Kerem Pekkan, and David A Vorp.
    • Fondazione Ri.MED, Palermo, Italy.
    • J. Vasc. Surg. 2013 May 1;57(5):1353-61.

    ObjectiveTo assess the biomechanical implications of excessive stent protrusion into the aortic arch in relation to thoracic aortic stent graft (TASG) collapse by simulating the structural load and quantifying the fluid dynamics on the TASG wall protrusion extended into a model arch.MethodsOne-way coupled fluid-solid interaction analyses were performed to investigate the flow-induced hemodynamic and structural loads exerted on the proximal protrusion of the TASG and aortic wall reconstructed from a patient who underwent traumatic thoracic aortic injury repair. Mechanical properties of a Gore TAG thoracic endoprosthesis (W. L. Gore and Assoc, Flagstaff, Ariz) were assessed via experimental radial compression testing and incorporated into the computational modeling. The TASG wall protrusion geometry was characterized by the protrusion extension (PE) and by the angle (θ) between the TASG and the lesser curvature of the aorta. The effect of θ was explored with the following four models with PE fixed at 1.1 cm: θ = 10 degrees, 20 degrees, 30 degrees, and 40 degrees. The effect of PE was evaluated with the following four models with θ fixed at 10 degrees: PE = 1.1 cm, 1.4 cm, 1.7 cm and 2.0 cm.ResultsThe presence of TASG wall protrusion into the aortic arch resulted in the formation of swirling, complex flow regions in the proximal luminal surface of the endograft. High PE values (PE = 2.0 cm) led to a markedly reduced left subclavian flow rate (0.27 L/min), low systolic perfusion pressure (98 mm Hg), and peak systolic TASG diameter reduction (2 mm). The transmural pressure load across the TASG was maximum for the model with the highest PE and θ, 15.2 mm Hg for the model with PE = 2.0 cm and θ = 10 degrees, and 11.6 mm Hg for PE = 1.1 cm and θ = 40 degrees.ConclusionsThe findings of this study suggest that increased PE imparts an apparent risk of distal end-organ malperfusion and proximal hypertension and that both increased PE and θ lead to a markedly increased transmural pressure across the TASG wall, a load that would portend TASG collapse. Patient-specific computational modeling may allow for identification of patients with high risk of TASG collapse and guide preventive intervention.Clinical RelevanceA potentially devastating complication that may occur after endovascular repair of traumatic thoracicaortic injuries is stent graft collapse. Although usually asymptomatic, stent graft collapse may be accompanied by adverse hemodynamic consequences. Numerous anatomic and device-related factors contribute to the development of collapse, but predictive factors have not yet been clearly defined. In the present study, we assessed the relevant hemodynamics and solid mechanics underlying stent graft collapse using a computational fluid-structure interaction framework of stent graft malapposition. Our findings suggest that both increased stent graft angle and extension into the aortic arch lead to a markedly increased transmural pressure across the stent graft wall, portending collapse. Patient-specific computational modeling may allow for identification of patients at high risk for collapse and aid in planning for an additional, prophylactic intervention to avert its occurrence.Copyright © 2013 Society for Vascular Surgery. Published by Mosby, Inc. All rights reserved.

      Pubmed     Free full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…