-
J Bone Joint Surg Am · Jun 2008
The use of long cemented stems for femoral impaction grafting in revision total hip arthroplasty.
- Rafael J Sierra, John Charity, Eleftherios Tsiridis, John A Timperley, and Graham A Gie.
- Department of Orthopedic Surgery, Mayo Clinic, Mayo Clinic College of Medicine, 200 First Street S.W., North 14, Rochester, MN 55905, USA. sierra.rafael@mayo.edu
- J Bone Joint Surg Am. 2008 Jun 1;90(6):1330-6.
BackgroundFollowing revision total hip arthroplasty involving femoral impaction grafting, fractures usually have occurred distal to a standard-length stem in an area of weakened bone that was left inadequately supported. The purpose of the present study was to determine whether the use of a long stem decreases the rate of femoral fracture after revision hip surgery. We hypothesized that the use of a long-stem femoral component would decrease the risk of these fractures.MethodsFrom 1991 to 2000, 567 revision total hip arthroplasties were performed with use of femoral impaction grafting. Of these, forty-two procedures in forty patients (average age, 73.8 years) were performed with use of a stem that was > or = 220 mm in length. The average number of previous revisions was 1.85. Thirty-four of the forty hips with preoperative radiographs had preoperative bone loss that was classified as grade III or IV according to the Endo-Klinik system. Major complications were recorded, and survival analysis was performed.ResultsNo patient was lost to follow-up. Sixteen patients (sixteen hips) died at an average of fifty-two months postoperatively. The average duration of clinical follow-up for the hips in which the implant survived for more than forty-eight months was 7.5 years. The rate of major postoperative complications was 29%. Two postoperative femoral fractures occurred. Six patients (six hips) required a femoral reoperation. The survival rate with revision hip surgery as the end point was 90% at both five and ten years. The rate of survival with any failure as the end point was 82% at five years and 64% at ten years.ConclusionsThe use of a long stem for femoral impaction grafting did not completely resolve the problem of postoperative fractures in these patients with substantial loss of bone stock undergoing revision hip surgery. Poor bone stock, technical errors, and other patient-related factors continue to account for the high postoperative fracture rate.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.