• Anaesth Intensive Care · May 1991

    Assessment of a new infusion pump for epidural PCA.

    • A M Baldwin, A H Ilsley, M T Kluger, and H Owen.
    • Department of Anaesthesia and Intensive Care, Flinders Medical Centre, Bedford Park, South Australia.
    • Anaesth Intensive Care. 1991 May 1;19(2):246-50.

    AbstractThe use of epidural fentanyl by patient-controlled analgesia (PCA) may be a useful method of providing high-quality postoperative analgesia on the general surgical ward. The successful use of this technique requires an infusion pump with specific characteristics. Three Provider 5500, newly-developed, battery-powered PCA pumps, were tested to determine their accuracy, threshold of occlusion alarm limits and stored volume characteristics. These measurements were repeated following the in-line addition of an 18 gauge epidural catheter and two 0.2 micron filters. Pumps delivered on average within 3% of stated infusion rates and within 3% of bolus dose size. Occlusion pressures generated were between 1200 and 1360 mmHg, while the mean stored volume was 0.12 ml. Accuracy of delivery was maintained at lower voltage inputs. Addition of the catheter failed to alter the accuracy of the pumps tested. Siphoning of fluid was possible on disconnection of cartridge from pump. This problem did not occur with the addition of an epidural catheter and filter. This device has features which make it suitable for the safe delivery of epidural PCA. Care, however, needs to be taken on changing cartridges to prevent accidental administration of a drug bolus to the patient.

      Pubmed     Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…