ObjectivesDocument fixation and healing of distal femur fractures stabilized by plate osteosynthesis using far cortical locking (FCL) screws.DesignProspective and observational.SettingTwo level 1 and 1 level 2 trauma centers.PatientsThirty-two consecutive patients with 33 distal femur fractures (AO/OTA types 33A, 33C).InterventionFractures were stabilized by plate osteosynthesis with MotionLoc FCL screws without supplemental bone graft or bone morphogenic proteins. Patients were followed up for a minimum of 1 year with functional and radiographic assessments obtained at postoperative weeks 6, 12, and 24 and computed tomography scans at week 12. If union was not confirmed within 1 year, follow-up was continued until union or revision surgery.Main Outcome MeasuresThe primary end point was fracture union in the absence of complications and secondary interventions. Fracture healing was defined by resolution of pain at the fracture site and cortical bridging on biplanar radiographs. Complications were defined by fixation failure, loss of reduction, implant breakage, infection, nonunion, and need for revision.ResultsThirty-one fractures were available for follow-up. None of the 125 FCL screws used for diaphyseal fixation broke or lost fixation. One of the 31 fractures displaced into varus (ΔVarus = 5.8 degrees). Thirty of the 31 fractures healed within 15.6 ± 6.2 weeks. At an average follow-up of 17 ± 4 months, there were 2 revisions: one to correct a malrotation at day 5 and one to treat a nonunion at 6 months.ConclusionsAbsence of implant and fixation failure suggests that dynamic plating of distal femur fractures with FCL screws provides safe and effective fixation.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.