• Ann Emerg Med · Sep 2016

    Observational Study

    Diagnostic Accuracy of Right Ventricular Dysfunction Markers in Normotensive Emergency Department Patients With Acute Pulmonary Embolism.

    • Anthony J Weekes, Gregory Thacker, Daniel Troha, Angela K Johnson, Jordan Chanler-Berat, H James Norton, and Michael Runyon.
    • Department of Emergency Medicine, Carolinas Medical Center, Charlotte, NC. Electronic address: anthony.weekes1@gmail.com.
    • Ann Emerg Med. 2016 Sep 1; 68 (3): 277-91.

    Study ObjectiveWe determine the diagnostic accuracy of goal-directed echocardiography, cardiac biomarkers, and computed tomography (CT) in early identification of severe right ventricular dysfunction in normotensive emergency department patients with pulmonary embolism compared with comprehensive echocardiography.MethodsThis was a prospective observational study of consecutive normotensive patients with confirmed pulmonary embolism. Investigators, blinded to clot burden and biomarkers, performed qualitative goal-directed echocardiography for right ventricular dysfunction: right ventricular enlargement (diameter greater than or equal to that of the left ventricle), severe right ventricular systolic dysfunction, and septal bowing. Brain natriuretic peptide and troponin cutoffs of greater than or equal to 90 pg/mL and greater than or equal to 0.07 ng/mL and CT right ventricular:left ventricular diameter ratio greater than or equal to 1.0 were also compared with comprehensive echocardiography.ResultsOne hundred sixteen normotensive pulmonary embolism patients (111 confirmed by CT, 5 by ventilation-perfusion scan) were enrolled. Twenty-six of 116 patients (22%) had right ventricular dysfunction on comprehensive echocardiography. Goal-directed echocardiography had a sensitivity of 100% (95% confidence interval [CI] 87% to 100%), specificity of 99% (95% CI 94% to 100%), positive likelihood ratio (+LR) of 90.0 (95% CI 16.3 to 499.8), and negative likelihood ratio (-LR) of 0 (95% CI 0 to 0.13). Brain natriuretic peptide had a sensitivity of 88% (95% CI 70% to 98%), specificity of 68% (95% CI 57% to 78%), +LR of 2.8 (95% CI 2.0 to 3.9), and -LR of 0.17 (95% CI 0.06 to 0.43). Troponin had a sensitivity of 62% (95% CI 41% to 80%), specificity of 93% (95% CI 86% to 98%), +LR of 9.2 (95% CI 4.1 to 20.9), and -LR of 0.41 (95% CI 0.24 to 0.62). CT had a sensitivity of 91% (95% CI 72% to 99%), specificity of 79% (95% CI 69% to 87%), +LR of 4.3 (95% CI 2.8 to 6.7), and -LR of 0.11 (95% CI 0.03 to 0.34).ConclusionGoal-directed echocardiography was highly accurate for early severe right ventricular dysfunction identification and pulmonary embolism risk-stratification. Brain natriuretic peptide was sensitive but less specific, whereas troponin had lower sensitivity but higher specificity. CT had good sensitivity and moderate specificity.Copyright © 2016 American College of Emergency Physicians. Published by Elsevier Inc. All rights reserved.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…