• Chest · Sep 1991

    Serial measurement of pulmonary mechanics assists in weaning from extracorporeal membrane oxygenation in neonates with respiratory failure.

    • M Garg, C D Lew, A D Ramos, A C Platzker, and T G Keens.
    • Division of Neonatology and Pediatric Pulmonology, Childrens Hospital of Los Angeles 90029.
    • Chest. 1991 Sep 1;100(3):770-4.

    AbstractExtracorporeal membrane oxygenation (ECMO) is a highly invasive therapy for intractable neonatal respiratory failure, and serious complications may occur with increasing duration of bypass. Weaning from bypass is empirical at present. Thus, there is a need to accurately predict when infants can be successfully decannulated. We hypothesized that pulmonary mechanics would reflect lung recovery and, therefore, predict successful weaning from ECMO. We measured pulmonary mechanics daily in 22 neonates, at gestational age of 37.8 +/- 0.6 weeks (SE) requiring ECMO for severe respiratory failure (oxygen index 66 +/- 6). Pulmonary resistance (Rpul), dynamic compliance (Cdyn), and tidal volume (VT) were measured. Rpul did not predict lung recovery. Cdyn within 24 hours of starting ECMO was 0.3 +/- 0.04 ml/cm H2O. Cdyn within 24 hours of weaning from ECMO was 1.2 +/- 0.09 ml/cm H2O (p less than 0.001). All 22 infants had Cdyn greater than 0.6 ml/cm H2O at the time of decannulation, but four infants (20 percent) with Cdyn less than 0.6 ml/cm H2O could not be weaned from ECMO within 20 hours (p less than 0.01). Thus, a minimum Cdyn of 0.6 ml/cm H2O is associated with successful weaning from ECMO. Cdyn of 0.8 ml/cm H2O provided better overall discrimination between those who could be successfully weaned from ECMO. We conclude that serial measurement of dynamic pulmonary compliance predicts successful weaning from ECMO.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

What will the 'Medical Journal of You' look like?

Start your free 21 day trial now.

We guarantee your privacy. Your email address will not be shared.